Sening®<br />

Innovative Tank Truck Systems<br />

4.2.1.2 Setup Table<br />

Setup parameter summary:<br />

Specification<br />

Euro <strong>Interface</strong> <strong>EMIS</strong><br />

<strong>Interface</strong> <strong>Description</strong><br />

Setup description TYPE VALUE1 VALUE2<br />

TDL-<br />

Kennung 800<br />

Feldindex<br />

Number of output drivers SET02 IO 0 to 4 4<br />

Level Gauge SET03 LG<br />

“N“ = No<br />

“Y“ = YES<br />

“D“ = Direct discharge<br />

5<br />

Tank truck type SET04 TT “M“ = Measuring vehicle<br />

“H“ = Hybrid vehicle<br />

6<br />

Number of compartments SET04 NC 01 to 24 7<br />

Number of overfill prevention devices SET04 OP 0 to 4 8<br />

Footvalve pressure balanced SET04 FB<br />

“N“ = No<br />

“Y“ = YES<br />

9<br />

Monitor pipeline fill level SET04 PS<br />

“N“ = No<br />

“Y“ = YES<br />

10<br />

Double sensors for remaining<br />

quantity<br />

SET04 DW<br />

Separate in-line valve controller SET04 LV<br />

Instrumentation cabinet lock SET04 UC<br />

Loading mode SET06 LM<br />

Turn on filling release valve SET06 LE<br />

Turn off filling release valve SET06 LD<br />

Automatic opening: SET06 AO<br />

Close compartments after filling: SET06 CC<br />

Compartment empty test SET06 CE<br />

Leave compartment open after<br />

empty test<br />

SET06 CO<br />

“N“ = No<br />

“Y“ = YES<br />

“N“ = No<br />

“Y“ = YES<br />

“N“ = No<br />

“Y“ = Yes<br />

“T“ = Truck<br />

“C“ = Compartment<br />

“L“ = Loading Mode<br />

“C“ = Connected<br />

“C“ = Compartment-Error<br />

“L“ = Loading-Error<br />

“S“ = System-Error<br />

“Y“ = Yes<br />

“N“ = No<br />

“M“ = NOT when<br />

manually entering<br />

loading plan<br />

“N“ = No<br />

“Y“ = YES<br />

“N“ = No<br />

“Y“ = Yes, WITHOUT<br />

override<br />

“O“ = Yes, WITH<br />

override<br />

(Override)<br />

“N“ = No<br />

“Y“ = YES<br />

MNF19002EUS / DOK-411E Rev. 2.00 / MB / jp / Juli 2008 31<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

17<br />

18<br />

19<br />

20<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

A<br />

Variablendefinition