Sening®<br />
Innovative Tank Truck Systems<br />
Examples for TDL data records:<br />
Event / sensor TYPE VALUE1 VALUE2<br />
Compartment status CFS CoNo<br />
TDL 40,S,V1, ,(0) (1) (1) () (2) () >> V2[..]<br />
CFS,3,4 >> 40,S,3,,2<br />
CFS,4,3 >> 40,S,4<br />
Seal status CST CoNo<br />
TDL 40,S,V1, , ,(2) (2) (1) (3) (3) (0) >> V2[..]<br />
CST,5,S >> 40,S,5,,,1<br />
CST,3,? >> 40,S,3,,,0<br />
Loading mode<br />
PKNG CoNo<br />
Specification<br />
Euro <strong>Interface</strong> <strong>EMIS</strong><br />
<strong>Interface</strong> <strong>Description</strong><br />
“0“ = empty<br />
“1“ = not empty<br />
“2“ = remaining quantity (not empty)<br />
“3“ = unknown<br />
“4“ = Full<br />
“5“ = Fault<br />
“E“ = empty (not sealed)<br />
“R“ = remaining quantity (not empty)<br />
“S“ = sealed<br />
“L“ = second sealing when loading<br />
“D“ = second sealing when discharging<br />
“?“ = unknown<br />
“0“ = end of loading<br />
or<br />
PrCo at start of loading<br />
TDL 41,S,V1, ,1 / 41,S,V1,V2,1<br />
PKNG,5,0 >> 41,S,5, ,1 Ende der Beladung KaNr 5<br />
PKNG,5,3 >> 41,S,5,3,1 Start der Beladung KaNr 5, PrCo 3<br />
MNF19002EUS / DOK-411E Rev. 2.00 / MB / jp / Juli 2008 39<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
A<br />
Variablendefinition