29.11.2012 Views

EMIS Interface Description - Measurement Solutions

EMIS Interface Description - Measurement Solutions

EMIS Interface Description - Measurement Solutions

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Sening®<br />

Innovative Tank Truck Systems<br />

Examples for TDL data records:<br />

Event / sensor TYPE VALUE1 VALUE2<br />

Compartment status CFS CoNo<br />

TDL 40,S,V1, ,(0) (1) (1) () (2) () >> V2[..]<br />

CFS,3,4 >> 40,S,3,,2<br />

CFS,4,3 >> 40,S,4<br />

Seal status CST CoNo<br />

TDL 40,S,V1, , ,(2) (2) (1) (3) (3) (0) >> V2[..]<br />

CST,5,S >> 40,S,5,,,1<br />

CST,3,? >> 40,S,3,,,0<br />

Loading mode<br />

PKNG CoNo<br />

Specification<br />

Euro <strong>Interface</strong> <strong>EMIS</strong><br />

<strong>Interface</strong> <strong>Description</strong><br />

“0“ = empty<br />

“1“ = not empty<br />

“2“ = remaining quantity (not empty)<br />

“3“ = unknown<br />

“4“ = Full<br />

“5“ = Fault<br />

“E“ = empty (not sealed)<br />

“R“ = remaining quantity (not empty)<br />

“S“ = sealed<br />

“L“ = second sealing when loading<br />

“D“ = second sealing when discharging<br />

“?“ = unknown<br />

“0“ = end of loading<br />

or<br />

PrCo at start of loading<br />

TDL 41,S,V1, ,1 / 41,S,V1,V2,1<br />

PKNG,5,0 >> 41,S,5, ,1 Ende der Beladung KaNr 5<br />

PKNG,5,3 >> 41,S,5,3,1 Start der Beladung KaNr 5, PrCo 3<br />

MNF19002EUS / DOK-411E Rev. 2.00 / MB / jp / Juli 2008 39<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

A<br />

Variablendefinition