EMIS Interface Description - Measurement Solutions
EMIS Interface Description - Measurement Solutions
EMIS Interface Description - Measurement Solutions
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Sening®<br />
Innovative Tank Truck Systems<br />
Specification<br />
Euro <strong>Interface</strong> <strong>EMIS</strong><br />
<strong>Interface</strong> <strong>Description</strong><br />
Direction Telegram<br />
<strong>EMIS</strong> SET,METER,ORDERS,ORDERCOUNT=“3“<br />
OBC <br />
<strong>EMIS</strong> REQUEST,ADMIN,STATUS<br />
OBC <br />
REPORT,ADMIN,STATUS,LASTERROR="2002:value out of range";<br />
MODE="READY"<br />
<strong>EMIS</strong> <br />
The ORDERCOUNT variable is set to a number that doesn’t match the number of presets<br />
received by <strong>EMIS</strong> (see step 6).<br />
� OBC must perform error treatment (e.g. repeat from step „0“)<br />
9 - Print header<br />
Direction Telegram<br />
<strong>EMIS</strong> SET,PRN,STATUS,MODE=“OBC“<br />
OBC <br />
The printer is now assigned to the OBC.<br />
� Proceed with the program.<br />
Direction Telegram<br />
<strong>EMIS</strong> SET,PRN,STATUS,MODE=“OBC“<br />
OBC <br />
<strong>EMIS</strong> REQUEST,ADMIN,STATUS<br />
OBC <br />
OBC REPORT,ADMIN,STATUS,LASTERROR="3000:no write access";<br />
MODE="READY"<br />
<strong>EMIS</strong> <br />
<strong>EMIS</strong> REQUEST,PRN,STATUS,MODE<br />
OBC <br />
OBC REPORT,PRN,STATUS,MODE=“METER“<br />
<strong>EMIS</strong> <br />
The printer access was rejected by <strong>EMIS</strong> since another device (a measuring system in the<br />
example above) is occupying the printer.<br />
� OBC must perform error treatment (e.g. repeat requesting printer access).<br />
MNF19002EUS / DOK-411E Rev. 2.00 / MB / jp / Juli 2008 63<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
A<br />
Programming Details