29.11.2012 Views

EMIS Interface Description - Measurement Solutions

EMIS Interface Description - Measurement Solutions

EMIS Interface Description - Measurement Solutions

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Specification<br />

Euro <strong>Interface</strong> <strong>EMIS</strong><br />

<strong>Interface</strong> <strong>Description</strong><br />

TDL,GPS<br />

Sening®<br />

Economic Tank Truck Systems<br />

The two PDA and Trailer variables are available for the GPS information. In the trailer variable the<br />

<strong>EMIS</strong> can provide GPS information which it has received form an <strong>EMIS</strong>-connected GPS module.<br />

Example:<br />

Direction Telegram<br />

<strong>EMIS</strong> REQUEST,TDL,GPS,Trailer<br />

OBC <br />

OBC<br />

REPORT,TDL,GPS,TRAILER=8,20040901100139,-<br />

010.519043,+53.532944,0000,06,1.10,,4.4,201.0<br />

<strong>EMIS</strong> <br />

In the PDA variable, the OBC can provide the <strong>EMIS</strong> with GPS information given that the GPS<br />

module is installed at the OBC. Whilst <strong>EMIS</strong> saves this information, it does not use it for internal<br />

purposes.<br />

Example:<br />

Direction Telegram<br />

<strong>EMIS</strong><br />

SET,TDL,GPS,PDA=8,20050901160547,+010.999999,-<br />

53.000000,0000,06,1.10,,60.4,221.8<br />

OBC <br />

…<br />

<strong>EMIS</strong> REQUEST,TDL,GPS,PDA<br />

OBC <br />

OBC<br />

REPORT,TDL,GPS,TRAILER=8,20050901160547,+010.999999,-<br />

53.000000,0000,06,1.10,,60.4,221.8<br />

<strong>EMIS</strong> <br />

TDL,PRN,Port<br />

1 to 10 values can be saved in the Port variable. However, the printer installed at the <strong>EMIS</strong> is<br />

always used irrespective of the value.<br />

<strong>EMIS</strong> does not support any sensoring on paper recognition at the printer. That is why the Staus=0<br />

(printer ready) is always returned even when no printer has been parameterised at the <strong>EMIS</strong>. The<br />

CMD variable is not supported i.e. whilst values can be written into the variable, they produce no<br />

effects.<br />

Apart from these limitations, the printer is controlled as described in the E7 specification.<br />

TDL,AUX<br />

An output is supported by the QAS system (see QAS,AUX,OutRelease). This output can also be<br />

accessed with TDL,AUX,OUT(1). The output is passive at 0 and active at 1. TDL,AUX,OUT(10) is<br />

a special feature. The effect of this variable being set to 0 is for the event request to be transmitted<br />

with setup information. No setup information is transmitted should the variable have the 1 value<br />

(see QAS,SETUP,NoSeP).<br />

92 Rev. 2.00 / MB / jp / Juli 2008 MNF19002EUS / DOK-411E