13.07.2015 Views

Technical Report for the Maricunga Gold Mine - Kinross Gold

Technical Report for the Maricunga Gold Mine - Kinross Gold

Technical Report for the Maricunga Gold Mine - Kinross Gold

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Kinross</strong> <strong>Gold</strong> Corporation<strong>Maricunga</strong> <strong>Mine</strong> <strong>Technical</strong> <strong>Report</strong>13.4.4 Analysis of QA/QC DataFor <strong>the</strong> 2002-2003 drilling program all standard, blank and duplicate results were sent to Dr.Smee <strong>for</strong> analysis. Duplicate results were analyzed <strong>for</strong> precision and plotted on ThompsonHowarth graphs. Dr. Smee found <strong>the</strong> error rate and duplicate variance normal <strong>for</strong> porphyrygold deposits. In his final report, (July 20,2003) he concluded <strong>the</strong> gold assay database to beof commercial quality but raised concerns about eight of <strong>the</strong> 650 ALS Chemex digital files.All eight files, containing failures, had already been reanalyzed, were determined to havehad CMM field labelling errors, or were duplicated assay sets.The 2006 QA/QC data was compiled as it was received by <strong>the</strong> geologists at <strong>the</strong> site. Anyanomalous results were flagged and <strong>the</strong> lab contacted directly to discuss <strong>the</strong> variationsobserved. A series of samples representing approximately 10% of <strong>the</strong> total were also sent toALS Chemex as an independent check.13.4.5 Referee LaboratoryAssayers Canada (Assayers), Vancouver, was selected as <strong>the</strong> referee laboratory <strong>for</strong> <strong>the</strong>program. Assayers Canada has achieved Certificates of Laboratory Proficiency from <strong>the</strong>Standards Council of Canada <strong>for</strong> precious and base metal analysis. One pulp per ALSChemex batch of 40 was selected at random, including <strong>the</strong> CMM standards, blanks andduplicates. Additionally one of <strong>the</strong> 3 CMM standards was inserted in this sample stream tocheck Assayers at a frequency of 1 per 40. Three batches of checks (631 samples in total)were sent to Assayers over <strong>the</strong> duration of <strong>the</strong> program. Results were <strong>for</strong>warded to Dr.Smee who concluded that <strong>the</strong> two labs essentially agreed on gold and cyanide soluble goldanalysis within normal precision limits.13.4.6 Statement of Author’s OpinionThe author concurs with Dr. Smee’s opinion that <strong>the</strong> slight variations observed were withinnormal precision limits.52

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!