13.07.2015 Views

standards / manuals / guidelines for small hydro development - AHEC

standards / manuals / guidelines for small hydro development - AHEC

standards / manuals / guidelines for small hydro development - AHEC

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

i. Tension 18,000ii. Compression 18,000 – 76 l/r where l/r is less than 150 and 13,000 – 48l/r where l/r is more than 150iii. Shear on 13,500boltsiv. Bearing on 27,000bolts2.8 GIS SubstationsAdvancement in the use of SF6 as an insulating and interrupting medium have resulted inthe <strong>development</strong> of gas insulated substations. Environment and/or space limitations mayrequire the consideration of GIS (gas insulated substation) equipment. This equipmentutilizes SF6 as an insulating and interrupting medium and permits very compactinstallations. GIS substation are preferable to air insulated system ((AIS) because offollowing reasons:i) Compact design reduces space requirementsii) Higher reliabilityiii) Life cycle costs and safety are better because GIS is maintenance freeiv) Location advantage especially in areas (town) where space costs are highv) Environmental advantage as rain, dust, snow, ice, salt etc. do not affect thehermetically sealed metal clad GISThree-phase or single-phase bus configurations are normally available up to 145 kVclass, and single phase bus to 500 kV and higher, and all equipment (disconnect/isolatingswitches, grounding switches, circuit breakers, metering current, and potentialtrans<strong>for</strong>mers, etc.) are enclosed within an atmosphere of SF6 insulating gas. The superiorinsulating properties of SF6 allow very compact installations.GIS installations are also used in contaminated environments and as a means of deterringanimal intrusions. Although initial costs are higher than conventional substations, a<strong>small</strong>er substation footprint can offset the increased initial costs by reducing the land areanecessary <strong>for</strong> the substation.2.8.1 GIS Compact SwitchgearCompact sub-station with gas insulated switchgear may be considered in following cases.i) Installations in areas with high risk of pollution and corrosion from industrialplants or by marine and desert climates.ii) Applications involving use of metal clad switchgear with components ofconventional design to minimize area requirement.iii) Underground substationsiv) Outdoor installation where space is not easily available1-16

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!