13.07.2015 Views

standards / manuals / guidelines for small hydro development - AHEC

standards / manuals / guidelines for small hydro development - AHEC

standards / manuals / guidelines for small hydro development - AHEC

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Section –3Selection of Power Trans<strong>for</strong>mer1.0 GeneralPower trans<strong>for</strong>mers function is to convert electric power from one voltage level toanother. In <strong>hydro</strong>electric plants, step up trans<strong>for</strong>mer per<strong>for</strong>m the task of delivering powerproduced by the generators to the transmission system. Most of these trans<strong>for</strong>mers areunit connected i.e. directly connected to generators with or without a generator breaker.These power trans<strong>for</strong>mers are generator trans<strong>for</strong>mers. Power trans<strong>for</strong>mers are liquidimmersed. Power trans<strong>for</strong>mers are located outside preferably in the switchyard /ortrans<strong>for</strong>mer deck in powerhouse. These <strong>guidelines</strong> are <strong>for</strong> generators/power trans<strong>for</strong>mersused in SHP <strong>for</strong> outdoor switching i.e. 11 kV to 220 kV.1.1 Relevant national and international <strong>standards</strong> in this connection are as follows:IS: 2026 (Part 1 to 4) - Specifications <strong>for</strong> Power Trans<strong>for</strong>merIS: 2099 - Bushings <strong>for</strong> alternating voltage above 1000VIS: 3639 - Fittings and accessories <strong>for</strong> power trans<strong>for</strong>merIEC: 60076 (Part 1 to 5) - Specifications <strong>for</strong> Power Trans<strong>for</strong>merCBI & P - Manual on trans<strong>for</strong>mer (oil immersed)(Publication No. 295-2007)IS: 11802.0 Generator Trans<strong>for</strong>mersPower trans<strong>for</strong>mer which step up the power produced by <strong>hydro</strong>electric generating units(0.415 to 11 kV) to a level which matches the sub transmission/transmission systemvoltage (typically 12 kV to 245 kV class) <strong>for</strong> range of power houses under considerationsare 2 winding oil immersed trans<strong>for</strong>mers.Three Phase Versus Single Phase Trans<strong>for</strong>merThree phase generator trans<strong>for</strong>mers should be used unless transport limitations or otherspecial reasons require use of single-phase trans<strong>for</strong>mer because of the following reasons.a) Higher efficiency than three single-phase units of equivalent capacity.b) Smaller space requirements and reduction in weight and dimensions.c) Lower installed cost.d) Lower probability of failure when properly protected by surge arrestors, thermaldevices and oil cooling and preservation system.3-1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!