7.0 Trans<strong>for</strong>mer StudiesIt is recommended that following studies be carried out <strong>for</strong> trans<strong>for</strong>mers 72.5 kV andabove from economic considerations.a) Type of coolingb) Insulation levelc) Departure from normal design impedance8.0 Electrical Characteristics8.1 Type of Trans<strong>for</strong>mer and Operating ConditionsAll trans<strong>for</strong>mers, should be oil immersed and may be either core or shell type and shouldbe suitable <strong>for</strong> outdoor installation. Normally oil immersed trans<strong>for</strong>mer should beprovided with conservator vessels. Where sealed trans<strong>for</strong>mers are specified, there will beno conservator but adequate space will be provided <strong>for</strong> expansion of oil withoutdeveloping undue pressure.Trans<strong>for</strong>mers designed <strong>for</strong> mixed cooling should be capable of operating under thenatural cooled condition upto the specified load. The <strong>for</strong>ced cooling equipment shouldlcome into operation by pre-set contacts in WTI and the trans<strong>for</strong>mer will operate as <strong>for</strong>cedcooled unit.Trans<strong>for</strong>mer should be capable of remaining in operation at full load <strong>for</strong> 10 minutes afterfailure of blowers without the calculated winding hot-spot temperature exceeding 150 0 C.Trans<strong>for</strong>mer fitted with two coolers each capable of dissipating 50% of the losses atcontinuous maximum rating (CMR) should be capable of remaining in operation <strong>for</strong> 20minutes in the event of failure of the blower associated with one cooler without thecalculated winding hot-spot temperature exceeding 150 0 C.8.2 Continuous Maximum Rating and OverloadsTrans<strong>for</strong>mers provided with mixed cooling should comply, as regards its ratingtemperature rise and overloads, with the appropriate requirements of IS: 2026 whenoperating with natural cooling and with mixed cooling.All trans<strong>for</strong>mers, except where stated should be capable of operation continuously, inaccordance with IS: loading guide at their CMR and at any ratio. In case bi-directionalflow of power is required, that should be specifically stated by the purchaser.Temperature rise test should be per<strong>for</strong>med at the tapping as desired by the purchaser. Ifnothing has been stated by the purchaser, the test should be carried out at the tapping withthe highest load losses.3-5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!