13.07.2015 Views

standards / manuals / guidelines for small hydro development - AHEC

standards / manuals / guidelines for small hydro development - AHEC

standards / manuals / guidelines for small hydro development - AHEC

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

iii) during arcing of SF6 breaker, no carbon dioxide is <strong>for</strong>med and hence no reductionof dielectric strength.iv) SF6 breaker is silent in operation and moisture ingression into the gas cycle isalmost nil.v) SF6 breaker per<strong>for</strong>mance is not affected due to variation in atmosphericconditions.vi) SF6 breaker is compact in size and electrical clearances are drastically reduced.Disadvantages: The only disadvantage of using SF6 to some extent is suffocation. Incase of leakage in the breaker tank, this gas, being heavier than air settles in thesurroundings and may lead to suffocation of the operating personnel. However, it isnon-poisonous.3.3 Evaluation of SF6 and Vacuum Switching TechnologiesSI. No.1Criteria2SF 6 circuit breaker3Vacuum circuit breaker4I. SWITCHING DUTIES1. Summated breakingcurrent capacity2. Critical switchingi. Motor, Reactors <strong>small</strong>inductive current.ii. Capacitorsiii. Over head and cablefeeders.iv. Switching of arcfurnaces.3. Suitability of single andmulti shot auto reclosecycles.To 50 times rated short circuitbreaking current To 10,000 timescontinuous rated current.Very well suited Over voltagegenerally under 2.5 p.u. Normallyno action necessary to limit overvoltages.Well suited. Restrike free. In specialcases reactors may be necessary tolimit in rush current - Low overvoltage.Very well suited-Restrike free.Only suitable in applicable withcomparatively low number ofoperations per day.Very well suitedTo 100 times rated short circuitbreaking current To 20,000times continuous rated current.Well suited. Under certaincircumstances steps may benecessary to limit over voltagesbecause of possibility of virtualcurrent chopping. Use of surgearresters recommendedSuited. Generally Restrike free.In special cases reactors may benecessary to limit in rushcurrent-Reignition and restrikespossible in certain cases due tostatistical scatter of breakdownvoltage in vaccum.Very well suited Restrike free.Suitable also <strong>for</strong> applicationswith very high number ofoperations (over 100 co-per day.Very well suited.SI. No.1Criteria2SF 6 circuit breaker 3Vacuum circuit breaker4II. MAINTAINABILITY4-4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!