OFAFOil Immersed with <strong>for</strong>ced oil circulation Forced Air CooledTrans<strong>for</strong>mers when located in powerhouse should be sited so that unrestricted ambient aircirculation is allowed. The maximum trans<strong>for</strong>mer rating should match maximumgenerator rating with <strong>for</strong>ced cooling in dual rating trans<strong>for</strong>mers, which are commonlyemployed. The rating of these dual rated trans<strong>for</strong>mers is usually as follows:ONAN/OFAFONAN - 60%OFAF - 100%The rating under ONAF condition although not guaranteed should be about 80%.Standby cooling capacity should be provided <strong>for</strong> different type of <strong>for</strong>ced cooling asfollows as per Central Board of Irrigation and Power Manual on Trans<strong>for</strong>mer.ONAN/OFAF-2 – 50% group2 – 100% pump of which one will be standby,2 – Standby fans one in each 50% groupOr3 – 50% group with independent pump andfans out of which one group to act as standby.6.0 Temperature Rise, Overload Capacity And Continuous RatingConservative value of temperature rise, overload capacity and continuous rating oftrans<strong>for</strong>mer located in the switchyard should be specified. For the purpose ofstandardization of maximum temperature rise of oil and windings, the following ambienttemperatures are recommended by CBI & P.Cooling mediumMaximum ambient temperatureMaximum daily average ambient temperatureMaximum yearly weighted average temperature: Air: 50 0 C: 40 0 C: 32 0 CWith the above ambient temperature condition the temperature rises <strong>for</strong> powertrans<strong>for</strong>mers as per CBI & P are as given below:Oil 0 CWinding 0 C50 55However more conservative temperature rise are specified <strong>for</strong> generator, trans<strong>for</strong>mers.Reference ambient temperatures and climatic conditions and temperature rise specified<strong>for</strong> generators trans<strong>for</strong>mer at Mukerian stage II in Punjab given in Annexure 3.1.3-4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!