of volumetric variation of oil due to temperature changes-stainless steel bellows/Nitrogenshould be provided. In case Nitrogen is used the supplier should ensure that gas is filledat suitable pressure to take care of the expansion & compression of nitrogen gas. Theequipment should be provided with oil level gauge and pressure relieving device capableof releasing abnormal internal pressures. The secondary terminals should be brought outin a compartment on one side of the equipment <strong>for</strong> easy access. The secondary tapsshould be adequately rein<strong>for</strong>ced to withstand normal handling without damage.Equipment should be provided with power factor terminals <strong>for</strong> testing loss angle (Tandelta). The equipment should also be provided with drain valve, sampling plug to checkdeterioration of oil characteristics and replacement of oil at site. Means adopted <strong>for</strong>sealing the CTs hermetically and to absorb the variation in volume of oil due totemperature variation by way of provision of stainless steel volume adjustable bellows orother means should be clearly brought out in the tender. Rubber or PVC/syntheticbellows <strong>for</strong> the purpose should not be accepted. The secondary terminal of CTs should beprovided with short circuiting arrangement.b) 11 kV ClassWindings: Change in the CT ratio shal be obtained by providing tapings in the secondarywinding. The primary bar and secondary windings shall be of copper.Core: The core of the CT shall invariably be of torroidal type. The magnetic circuit shallbe of high grade, non-ageing electrical silicon laminated steel of low hysterias loss andhigh permeability to ensure high accuracy at both normal and over currents.4.4 Terminal Connectors 33 kV and AboveAll current trans<strong>for</strong>mers should be provided with appropriate number of solderless clamptype primary connectors suitable <strong>for</strong> ACSR conductor and should be suitable <strong>for</strong>horizontal as well as vertical take off with single conductor as per actual requirement.4.5 Type of Mountinga) 12 kV & AboveThe current trans<strong>for</strong>mers should be suitable <strong>for</strong> mounting on steel structures. Thenecessary flanged, bolts etc. <strong>for</strong> the base of CTs should be galvanized.b) 11 kV Outdoor TypeThe CT shall be supported on a suitable post insulator to be mounted on a pedestal/steelstructure. Mounting flanges, bolts, etc. shall be hot dip galvanized and shall be suppliedalong with the CT. Suitable mounting holes shall be provided at the base <strong>for</strong> clamping tothe structures.2-9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!