depends upon site conditions e.g. <strong>for</strong> 2 x 10 M Mukerian SHP 72.5 kV switchyard(Punjab Plains), it was specified as follows and is recommended <strong>for</strong> similar breakers.i) Reference ambient temperature in shade = 50 0 Cii) Reference temperature under direct rays = 60 0 Cof the sun <strong>for</strong> limiting temperature riseas per IS: 99213.2 RatingEach isolating switch should have the following particulars (table 2.3.2) under the siteconditions <strong>for</strong> the system under design.Table 2.3.21. Highest system voltage 72.5 kV 36 kV 12 kV2. Rated frequency (cycle/second) 50 c/s 50 c/s 50 c/s3. Rated lightning impulse withstand voltage (withoutarcing horn)i) To earth and between poles (kV Peak)ii) Across the isolating distance (kV peak)4. Rated one-minute power frequency wet withstandvoltagei) To earth and between poles (kV rms)ii) Across the isolating distance (kV rms)Voltage against ground and between poles2-3325 kV(+ ve & - ve waveto earth &between poles)140 kV(against ground &between poles)170 kV195 kV70 kV80 kV75 kV85 kV28 kV32 kV5. Continuous rated current (Amps) 1600 A 630 A 400 A6. Short time current ratingsi) For one second not less than kA (rms) 20 kA16 kA 16 kAii) For 3 secondsTo be stated To be To be7. Rated peak withstand current kA (peak) in closedpositionstated statedTo be stated 40 kA 40 kA8. Trans<strong>for</strong>mer off-load breaking capacity A (rms) To be stated 6.3 kA 6.3 kA9. Line charging capacity A (rms) To be stated 6.3 A 2.5 A10. Rated DC voltage <strong>for</strong> auxiliary circuits A (rms) To be stated11. Rated supply frequency and voltage of AC operatingdevicesIsolators 36 kV and 12 kV: should con<strong>for</strong>m to IS: 9920Isolated 72.5 kV & above should con<strong>for</strong>m to IS: 99213 phase 415 volts and single phase 220V ACThe location of disconnect switches in substations affects substation layouts.Maintenance of the disconnect contacts is also a consideration in the layout. In somesubstations, the disconnects are mounted at high positions either vertically orhorizontally. Although such substations occupy <strong>small</strong>er areas, the maintenance of

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!