COMBIMASTER & MICROMASTER Integrated8.8.4 Electromechanical Brake ControlThe electromechanical brake control, allows theCOMBIMASTER to directly control an electromechanicalbrake.The brake control fits in place of the standard cover for theinverter unit. Full IP65 environmental protection ismaintained.The unit provides an output to drive the coil of a DCelectromechanical brake. It can be configured for both fastand slow operation of the coil. The unit is set up using theparameters P062, P063 and P064, which allows full control ofthe brake release time, and brake stopping time.Brake coil voltage output will be 180VDC for 400V mainsinput, and 205VDC for 230V mains input.Note that the coil voltage for 400V units of 180VDC is notsuitable for the standard Siemens electromechanical brakeoption G26.For other mains voltages, the coil voltage will be:0.9*Vmains for Vmains = 208V to 240V0.45*Vmains for Vmains = 380V to 500V8/34 Siemens DA 64 – 1998/99 (004/99