Standard ApplicationsMICROMASTERMICROMASTER VectorMIDIMASTER VectorSystem Specifications:MotorControl SystemDriveDrive Control Interface18.5 kW 400 V 3 phase squirrel cage motorClear Text Display unitMIDIMASTER Vector 6SE32 18.5 kW 400 VKeypad control with start, stop and motorised potentiometer (reverse and jog functionsdisabled)Parameter settings for this application which are changed from their defaults:Note that P009 must be set to 2 or 3 before parameter numbers above P009 can be modifiedNumber Value MeaningP006 2 Motorised potentiometer enabledP011 1 Motorised potentiometer adjustment settings stored on power downP016 3 Flying Start in forward direction enabledP077 2 Quadratic V/F curve selectedP080 0.86 Motor rating plate power factor = 0.86P082 1465 Motor rating plate speed = 1465 RPMP083 34.5 Motor rating plate current = 34.5 AP122 0 Reverse Key disabledP123 0 Jog Key disabledP125 0 Reverse direction disabledThe motor rating plate parameters correspond to a 1LA5 18.5 kW 4 pole motor connected in Star.(18.5kW)4/8 Siemens DA 64 – 1998/99 (04/99)