WIRES FLUX CORED<br />

STOODY SOS 308L<br />

5<br />

Shieldcrome 308LT-O is a self shielded (or open arc) stainless steel flux cored<br />

wire developed for a wide range of “in situ” downhand welding applications on<br />

19Cr/10Ni type stainless steels including type 201, 202, 301, 302, 304 and 304L.<br />

Shieldcrome 308LT-O is ideal for fast fillet and butt welding applications in the flat<br />

and horizontal-vertical positions.<br />

Classifications:<br />

AWS/ASME-SFA A5.22:<br />

E308LTO-3.<br />

WTIA Tech Note 4/AS 2576:<br />

1315-B7.<br />

Ferrite Number: 8.0<br />

Features:<br />

SHIELDCROME Stainless Steel Flux Cored Wires.<br />

Convenient Self Shielded (Open Arc) Operation For “In situ or Outdoor Applications.<br />

High Deposition Rate Downhand Welding.<br />

For downhand welding application on 19Cr/10Ni type stainless steels including type<br />

301, 302, 304 and 304L.<br />

Typical All Weld Metal Analysis:<br />

C: 0.02% Mn: 1.20% Si: 0.50%<br />

Cr: 20.80% Ni: 10.2%<br />

Typical All Weld Metal Mechanical Properties:<br />

Tensile Strength<br />

600 MPa<br />

Elongation 43%<br />

Actual weld metal mechanical properties achieved with Shieldcrome wires are<br />

influenced by many factors including, base metal analysis, welding parameters / heat<br />

input used, number of weld passes and run placement etc. Please consult your nearest<br />

CIGWELD branch for welding procedure recommendations.<br />

Comparable CIGWELD <strong>Product</strong>s:<br />

Shieldcrome 308LT all positional gas shielded FCAW wire<br />

AWS A5.22:<br />

E308LT1-1 / E308LT1-4.<br />

Shieldcrome 308LTD downhand gas shielded FCAW wire<br />

AWS A5.22:<br />

E308LT0-1 / E308LT0-4.<br />

Autocraft 308LSi GMAW wire<br />

AWS A5.9:<br />

ER308LSi.<br />

Comweld 308L Gas / TIG rod<br />

AWS A5.9:<br />

ER308L.<br />

Satincrome 308L-17 electrode<br />

AWS A5.4:<br />

E308L-17.<br />

Recommended Shielding Gases:<br />

Not required.<br />

Packaging Data:<br />

Wire Diameter Wire Type Type Pack Weight Pack Part No.<br />

2.4 308LT-O Coil 22kg 11175400<br />

Operating Data:<br />

All welding conditions recommended below are for use with semi-automatic self shielded operation and DC electrode positive.<br />

Wire Diameter (mm) Current Range (amps) Voltage Range (volts) Electrode Stickout E.S.O. (mm) Welding Positions<br />

2.4 300-350 28-30 20-25 Flat<br />

2.4 300-350 28-30 20-25 HV Fillet<br />

These machine settings are a guide only. Actual voltage, welding current and E.S.O. used will depend on machine characteristics, plate thickness, run size, shielding gas and<br />

operator technique etc.<br />

STOODY SOS 309L<br />

CONSUMABLES<br />

Shieldcrome 309LT-O is a self shielded (or open arc) stainless steel flux cored wire<br />

developed for a wide range of “in situ” downhand welding applications on matching<br />

309 and 309L stainless steels. Shieldcrome 309LT-O is also recommended for the<br />

dissimilar fillet and butt welding of other ‘300 series’ austenitic stainless steels to<br />

mild or low alloy steels and for the “buttering” of steels prior to the application of<br />

hardfacing.<br />

Classifications:<br />

AWS/ASME-SFA A5.22:<br />

E309LTO-3.<br />

WTIA Tech Note 4/AS 2576:<br />

1315-B7.<br />

Ferrite Number 15.0<br />

Features:<br />

SHIELDCROME Stainless Steel Flux Cored Wires.<br />

Convenient Self Shielded (Open Arc) Operation For “In situ” or Outdoor Applications.<br />

For Joining Dissimilar Steels or as a Buffer Layer Prior to Hard Surfacing.<br />

High Deposition Rate Downhand Welding.<br />

Typical All Weld Metal Analysis:<br />

C: 0.02% Mn: 1.20% Si: 0.5%<br />

Cr: 24.4% Ni: 12.6%<br />

Typical All Weld Metal Mechanical Properties:<br />

Tensile Strength<br />

610 MPa<br />

Elongation 38%<br />

Actual weld metal mechanical properties achieved with Shieldcrome wires are<br />

influenced by many factors including, base metal analysis, welding parameters / heat<br />

input used, number of weld passes and run placement etc. Please consult your nearest<br />

CIGWELD branch for welding procedure recommendations.<br />

Comparable CIGWELD <strong>Product</strong>s:<br />

Shieldcrome 309LT all positional gas shielded FCAW wire<br />

AWS A5.22:<br />

E309LT1-1 / E309LT1-4.<br />

Shieldcrome 309LTD downhand gas shielded FCAW wire<br />

AWS A5.22:<br />

E309LT0-1 / E309LT0-4.<br />

Autocraft 309LSi GMAW wire<br />

AWS A5.9:<br />

ER309LSi.<br />

Comweld 309L Gas / TIG rod<br />

AWS A5.9:<br />

ER309L.<br />

Satincrome 309Mo-17 electrode<br />

AWS A5.4:<br />

E309Mo-17.<br />

Recommended Shielding Gases:<br />

Not required.<br />

Packaging Data:<br />

Wire Diameter Wire Type Type Pack Weight Pack Part No.<br />

2.4 309LT-O Coil 22kg 11231200<br />

Operating Data:<br />

All welding conditions recommended below are for use with semi-automatic self shielded operation and DC electrode positive.<br />

Wire Diameter (mm) Current Range (amps) Voltage Range (volts) Electrode Stickout E.S.O. (mm) Welding Positions<br />

2.4 300-350 28-30 20-25 Flat<br />

2.4 300-350 28-30 20-25 HV Fillet<br />

These machine settings are a guide only. Actual voltage, welding current and E.S.O. used will depend on machine characteristics, plate thickness, run size, shielding gas and<br />