==> Press Enter at the <strong>VM</strong> READ prompt<br />

► Run the instvm dvd command:<br />

==> instvm dvd<br />

...<br />

HCPPLD8329I POSTLOAD EXEC ENDED SUCCESSFULLY<br />

...<br />

HCPI<strong>VM</strong>8392I INST<strong>VM</strong> ENDED SUCCESSFULLY<br />

This EXEC continues the installation process. This step should take about 4-8 minutes.<br />

<strong>The</strong> last message should be HCPI<strong>VM</strong>8392I INST<strong>VM</strong> ENDED SUCCESSFULLY<br />

► Load the recommended service. First IPL CMS then press Enter at the <strong>VM</strong> READ prompt:<br />

==> ipl cms<br />

==> Press Enter at the <strong>VM</strong> READ prompt<br />

Ready;<br />

► For z/<strong>VM</strong> 6.1, the service name is 6<strong>10</strong>1RSU1. Verify this file exists on the MAINT 500 disk:<br />

==> acc 500 c<br />

DMSACC724I 500 replaces C (2CC)<br />

==> listfile * * c<br />

6<strong>10</strong>1RSU1 SERVLINK C1<br />

► Run the SERVICE ALL command to apply the service:<br />

==> service all 6<strong>10</strong>1rsu1<br />

...<br />

This step should take about 3-6 minutes. <strong>The</strong> last message should be:<br />

40 <strong>The</strong> <strong>Virtualization</strong> <strong>Cookbook</strong> <strong>for</strong> RHEL 6<br />

<strong>VM</strong>FSRV2760I SERVICE processing completed successfully.<br />

► IPL CMS and run the put2prod command. This puts the service into production:<br />

==> ipl cms<br />

==> Press Enter<br />

Ready;<br />

==> put2prod<br />

This step should take about 2-4 minutes. <strong>The</strong> last message should be:<br />

<strong>VM</strong>FP2P2760I PUT2PROD processing completed successfully.<br />

A return code of 0 is ideal. You may get a return code of 4 and the message:<br />

<strong>VM</strong>FP2P2760I PUT2PROD process completed with warnings.<br />

In general on z/<strong>VM</strong>, a return code of 4 is acceptable. That means that only warnings were<br />

issued. A return code of 8 or greater generally means that errors were encountered.<br />

► Enter the following command to shutdown and re-IPL your system:<br />

==> shutdown reipl<br />

SYSTEM SHUTDOWN STARTED<br />

► You will lose the current session on the Integrated 3270 Console, but the system should<br />

come back in about 2-4 minutes.<br />

► After it comes back, the last message should be “Press enter or clear key to<br />

continue”. Press Enter and you should see a z/<strong>VM</strong> logon screen.<br />

Congratulations! You should now have a vanilla z/<strong>VM</strong> system installed.