==> link $page$ a03 a03 mr<br />

==> cpfmtxa a03 mvd852 label<br />

...<br />

==> cpfmtxa 124 mvd853 label<br />

...<br />

==> cpfmtxa 125 mvd854 label<br />

...<br />

► Now that the five volumes have been relabeled (sometimes called clipping the volumes,<br />

derived from a contraction of the z/OS term change label program), you can run the<br />

DIRECTXA command to update the directory:<br />

==> directxa user<br />

z/<strong>VM</strong> USER DIRECTORY CREATION PROGRAM - VERSION 6 RELEASE 1.0<br />

EOJ DIRECTORY UPDATED AND ON LINE<br />

HCPDIR494I User directory occupies 43 disk pages<br />

Ready(00005); T=0.01/0.01 15:45:51<br />

A return code of 5 is expected because the labels in the USER DIRECT file are different from<br />

the spool data in the currently running system.<br />

Finally, you are ready to issue a SHUTDOWN command.<br />

4.11.4 Shutting down your system and restarting it<br />

You will need an HMC console session <strong>for</strong> this step, if you are not already running from there.<br />

To test the changes you must shut your system down and then restart it. You cannot do a<br />

SHUTDOWN REIPL in this situation because you will have to do a FORCE start<br />

==> shutdown<br />

SYSTEM SHUTDOWN STARTED<br />

HCPSHU960I System shutdown may be delayed <strong>for</strong> up to 2<strong>10</strong> seconds<br />

Per<strong>for</strong>m the following steps to bring the system back up:<br />

► Open an HMC session<br />

► Select your LPAR<br />

► Use the circular arrow racetrack buttons to get to the CPC Recovery (or just Recovery)<br />

menu.<br />

► Double-click the Integrated 3270 Console menu item. A new window should appear.<br />

► Double-click the LOAD menu item. <strong>The</strong> Load Address (D850 in this example) and Load<br />

Parameter (SYSG) fields should be correct from the previous IPL.<br />

► Select the Clear radio button. <strong>The</strong> Load Address and Load Parameter fields should be<br />

correct from the previous IPL. Click OK<br />

► Click Yes on the Load Task Confirmation window.<br />

► Go back to the Integrated 3270 console. After a few minutes the Standalone Program<br />

Loader panel should appear. Use the TAB key to traverse to the section IPL Parameters<br />

and enter the value cons=sysg<br />

► Press the F<strong>10</strong> key to continue the IPL of your z/<strong>VM</strong> system. This should take 1-3 minutes.<br />

► At the Start prompt you have to specify a FORCE start, again because the spool volume<br />

label has changed:<br />

==> <strong>for</strong>ce drain<br />

► Do not change the time of day clock:<br />

68 <strong>The</strong> <strong>Virtualization</strong> <strong>Cookbook</strong> <strong>for</strong> RHEL 6