<strong>Operating</strong> <strong>Instructions</strong><br />
BUFALO Rondofix V3.0<br />
5.4. Emergency stopping<br />
Indication<br />
The emergency stop switch is effective in every operating mode. It serves to<br />
shut down the machine in dangerous situations. Every an emergency stop all<br />
subunits are without power.<br />
<strong>Operating</strong> the emergency stop switch cuts out the control voltage. This must be<br />
restored again after releasing the emergency stop switch by pressing the ON key.<br />
Opening the safety covers over the fixing station will also trigger an emergency stop.<br />
After closing the covers the control voltage must be switched on again.<br />
5.4.1. Linking other equipment<br />
If the EMERGENCY STOP circuit of other equipment is to be linked with the safety<br />
circuit of the BUFALO RONDOFIX, terminals have been provided for this. The<br />
connections are shown in the electrical diagram.<br />
The control system of the BUFALO RONDOFIX gives a pulse signal to other<br />
equipment.<br />
� 37 <strong>Operating</strong>s <strong>Instructions</strong> Edition 22. November 2007<br />
Bufalo Rondofix V3.0