<strong>Operating</strong> <strong>Instructions</strong><br />
BUFALO Rondofix V3.0<br />
7.6.6. Advance Rear<br />
The following is displayed:<br />
Causes:<br />
Advance Rear<br />
• The feed advance cylinder has not reached the rear limit switch (left) in automatic<br />
mode. The timeout has expired. Possibly the end limit switch is set incorrectly or is<br />
defect.<br />
Correction:<br />
• This error message must first be exited by pressing the "Enter" key on the terminal.<br />
Then switch the machine to manual operational mode. Move the cylinder back.<br />
Correct or exchange end limit switch.<br />
7.6.7. Fixer Front<br />
The following is displayed:<br />
Causes:<br />
Fixer Front<br />
• The drive cylinder has not reached the front limit switch (operator side) in<br />
automatic mode. The timeout has expired. Possibly the end limit switch is set<br />
incorrectly or is defect.<br />
Correction:<br />
• This error message must first be exited by pressing the "Enter" key on the terminal.<br />
Then switch the machine to manual operational mode. Advance the cylinder<br />
forwards. Correct or exchange end limit switch.<br />
7.6.8. Fixer Rear<br />
The following is displayed:<br />
Causes:<br />
Fixer Rear<br />
• The drive cylinder has not reached the rear limit switch (rear side) in automatic<br />
mode. The timeout has expired. Possibly the end limit switch is set incorrectly or is<br />
defect.<br />
Correction:<br />
• This error message must first be exited by pressing the "Enter" key on the terminal.<br />
Then switch the machine to manual operational mode. Move the cylinder to the<br />
rear. Correct or exchange end limit switch.<br />
Exit:<br />
• Press the "Enter" key on the terminal.<br />
� 59 <strong>Operating</strong>s <strong>Instructions</strong> Edition 22. November 2007<br />
Bufalo Rondofix V3.0