30.06.2013 Views

Progetto SIMEA - Automatica - Università degli Studi di Padova

Progetto SIMEA - Automatica - Università degli Studi di Padova

Progetto SIMEA - Automatica - Università degli Studi di Padova

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>SIMEA</strong> Stato dell’arte energetica <strong>degli</strong> e<strong>di</strong>fici<br />

1.2.9.6. Output<br />

24<br />

Doc.No 20100610.<strong>SIMEA</strong>.MR.03<br />

Versione 1<br />

The user can chose any of the calculated parameters for each construction layer, each thermal zone<br />

plus data from ambient climate, as output on hourly, weekly, monthly or perio<strong>di</strong>cal basis, in either tabular or<br />

graphic form. The variables can also be presented in "sum" graphs or tables. Finally the energy balances for<br />

each zone or the whole buil<strong>di</strong>ng can be shown. Outputs can be copied (graphics or numbers) for presentation<br />

in other programs.<br />

1.2.9.7. Computer Platform<br />

PC equipped with an Intel Pentium processor (min. 800 MHz) or compatible. Operating system:<br />

Windows NT version 4, SP3, Windows 2000, Windows XP, or Windows Vista.<br />

1.2.9.8. Programming Language<br />

MS-Visual C++.<br />

1.2.9.9. Strengths<br />

Analysis of the indoor thermal and moisture climate in complex buil<strong>di</strong>ngs or buil<strong>di</strong>ngs with special<br />

requirements for the indoor climate. Simultaneous simulation of energy and moisture transfer in buil<strong>di</strong>ng<br />

constructions. Multi zone natural air flow simulations. Intuitive graphic user interface. The Danish Buil<strong>di</strong>ng<br />

Research Institute is continuously updating BSim to accommodate changes and developments in the buil<strong>di</strong>ng<br />

industry.<br />

1.2.9.10. Weaknesses<br />

No standar<strong>di</strong>zed result reports. No possibility batch processing of simulation models at this time –<br />

typical simulation time for an average model is though only a few minutes on an up to date computer. No<br />

support of geometrical input from CAD tools in IFC file formats –this facility is presently being developed.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!