<strong>SIMEA</strong> Stato dell’arte energetica <strong>degli</strong> e<strong>di</strong>fici<br />

1.2.20. EE4 CBIP<br />

41<br />

Doc.No 20100610.<strong>SIMEA</strong>.MR.03<br />

Versione 1<br />

Designed to demonstrate a buil<strong>di</strong>ng's compliance to the requirements of the<br />

Commercial Buil<strong>di</strong>ng Incentive Program (CBIP) performance path approach. EE4<br />

CBIP is offered by Natural Resources Canada's Office of Energy Efficiency to<br />

buil<strong>di</strong>ng owners and developers for the design and construction of new<br />

commercial and institutional buil<strong>di</strong>ngs that use 25% less energy than similar<br />

buil<strong>di</strong>ngs built to the requirements of the Model National Energy Code for<br />

Buil<strong>di</strong>ngs (MNECB). EE4 CBIP may also be used to perform non-compliance<br />

energy analyses and thus to pre<strong>di</strong>ct a buil<strong>di</strong>ng's annual energy consumption, and<br />

to assess the impact of design changes to the buil<strong>di</strong>ng.<br />

1.2.20.1. Expertise Required<br />

Basic understan<strong>di</strong>ng of Windows. Knowledge of buil<strong>di</strong>ng modelling. Engineering background helpful<br />

but not required.<br />

1.2.20.2. Users<br />

1000<br />

1.2.20.3. Au<strong>di</strong>ence<br />

Mechanical, buil<strong>di</strong>ng, energy engineers and architects working for consulting firms, buil<strong>di</strong>ng owners<br />

and/or designers; buil<strong>di</strong>ng and energy-code verifiers; CBIP application reviewers.<br />

1.2.20.4. Input<br />

Basic information, envelope components areas and characteristics, characteristics of the buil<strong>di</strong>ng's<br />

HVAC, lighting and service water heating systems.<br />

1.2.20.5. Output<br />

Energy consumption and energy cost of proposed design and CBIP reference buil<strong>di</strong>ng. Summary and<br />

detailed compliance reports.<br />

1.2.20.6. Computer Platform<br />

PC-compatible, Windows NT or Windows 95/98/2000 operating system, IBM 486 or Pentium 75 with<br />

at least 16 MB RAM, 40 MB free <strong>di</strong>sk space, SVGA monitor with minimum 800 x 600 resolution.<br />

1.2.20.7. Programming Language<br />

Borland C++<br />

1.2.20.8. Strengths<br />

EE4 CBIP automatically generates a reference buil<strong>di</strong>ng to verify compliance to CBIP requirements<br />

using the performance path approach. EE4 CBIP can also be used in non-compliance mode to pre<strong>di</strong>ct a<br />

buil<strong>di</strong>ng's annual energy consumption and energy cost. Includes default libraries of common buil<strong>di</strong>ng plants,<br />

systems, construction assemblies and materials, lighting elements, fenestration and operating schedules.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!