HOOK-UP DIAGRAMS<br />
98<br />
Figure II-29<br />
Storage Cylinder with<br />
High Limit Protection<br />
Steam<br />
S<strong>up</strong>ply<br />
Float &<br />
Thermostatic<br />
Steam Trap<br />
Spira-tec<br />
Loss<br />
Detector<br />
Moisture<br />
Separator<br />
Figure II-30<br />
Condensate Drainage from Unit Heater<br />
Steam<br />
S<strong>up</strong>ply<br />
Strainer<br />
Note: The Liquid Expansion<br />
Steam Trap will automatically<br />
drain unit heater during periods<br />
of shutdown which will<br />
prevent damage due to corrosion.<br />
Alternate<br />
Location<br />
Check<br />
Valve<br />
Fail safe protection against excess temperatures is provided by a separate control<br />
valve, normally latched wide open. If the 130 self-acting control system<br />
detects a temperature overrun, or if the control system itself is damaged, a powerful<br />
spring is released in the HL10 unit and the high limit valve is driven closed.<br />
A switch is available as an extra to provide electrical warning that the device has<br />
been actuated.<br />
Strainer Valve<br />
HL10<br />
Overheat<br />
Protection<br />
Float &<br />
Thermostatic<br />
Steam Trap<br />
Liquid Expansion<br />
Steam Trap<br />
Spira-tec<br />
Loss<br />
Detector<br />
Self Acting<br />
Temperature<br />
Control<br />
Strainer<br />
Unit<br />
Heater<br />
Strainer<br />
Vacuum<br />
Breaker<br />
Spira-tec<br />
Loss<br />
Detector<br />
Liquid Expansion<br />
Steam Trap<br />
To Drain<br />
High Limit<br />
130 Sensor<br />
Temperature<br />
Control<br />
Sensor<br />
Float &<br />
Thermostatic<br />
Steam Trap<br />
Check<br />
Valve<br />
Storage<br />
Tank<br />
Hot Flow<br />
To<br />
Overhead<br />
Return<br />
Circ.<br />
Return<br />
To<br />
Condensate<br />
Return<br />
Cold<br />
S<strong>up</strong>ply<br />
Drain condensate<br />
by gravity where<br />
possible—<br />
especially to vac.<br />
return system