SYSTEM DESIGN<br />

44<br />

Flash Steam<br />

Flash Vessel Configurations<br />

Flash vessels can be either horizontal or vertical. For flash steam recovery (pressurized receiver) the vertical<br />

style is preferred because of its ability to provide better separation of steam and water.<br />

Horizontal<br />

Flash Vessel<br />

Condensate<br />

inlet<br />

Length<br />

Length = 2 x diameter or<br />

24" minimum<br />

Flash Steam<br />

outlet or vent pipe<br />

Condensate<br />

outlet<br />

Diameter<br />

For proper installation of flash vessels, controls and traps refer to<br />

Figures II-76, 77, 78, 79, 80, 81, 82, 83 (starting on page 120)<br />

The sour water condenser-reboiler is an important element<br />

in a refinery sulfur unit. Though the<br />

configuration/design will vary with the specific process<br />

used, the purpose and priority remain the same. Process<br />

water contaminated with ammonia and hydrogen sulfide<br />

gas (H2S) is stripped of those compounds for reuse. The<br />

remaining stream of contaminants goes to waste treatment.<br />

The process depends on accurate temperature<br />

control of the steam heated condenser-reboiler.<br />

40 psig steam is s<strong>up</strong>plied through a modulating control<br />

valve. Condensate is lifted 15 feet from the outlet at the<br />

bottom of the vertical condenser-reboiler to the overhead<br />

condensate receiver tank, which is maintained at 20 psig.<br />

Process load fluctuations and resultant turndown on the<br />

modulating steam control valve would have created a<br />

STALL situation, unacceptable process temperature control<br />

and reduced throughput.<br />

Figure 52: Flash Vessel Configurations<br />

Condensate<br />

inlet<br />

35% of<br />

height<br />

Flash steam outlet<br />

or vent pipe<br />

Diameter<br />

Condensate<br />

outlet<br />

Case in Action: Sour Water Condenser-Reboiler Temperature Control<br />

Vertical Flash<br />

Vessel<br />

Height = 3 x Diameter or<br />

36" minimum<br />

Solution<br />

A 3" x 2" PPF with 2-1/2" FTB 125 pump/trap combination<br />

was designed into the new project as was a VS 204 air<br />

vent. The installation was immediately successful.<br />

Benefits<br />

• With faster start-<strong>up</strong>, it came <strong>up</strong> to temperature faster<br />

than any other comparable unit, to date, at the refinery.<br />

This improves productivity.<br />

• The feed rate is higher than designed because the unit<br />

is able to operate efficiently at any degree of turndown.<br />

• Installation cost is several times less costly for the<br />

pump/trap combo than traditional level control system<br />

that would otherwise have been used.<br />

• Maintenance cost is lower, through elimination of electric/pneumatic<br />

controls and electric pumps used in a<br />

traditional level control system.