2000 Hook-up Book - Spirax Sarco
2000 Hook-up Book - Spirax Sarco
2000 Hook-up Book - Spirax Sarco
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
HOOK-UP DIAGRAMS<br />
114<br />
Figure II-62<br />
Draining High Pressure Reboiler<br />
Steam<br />
S<strong>up</strong>ply<br />
Figure II-63<br />
Draining Condensate to Vented Receiver and<br />
Lifting Condensate to Overhead Return Main<br />
Steam<br />
Space<br />
Strainer<br />
Strainer<br />
Spira-tec<br />
Loss Detector<br />
Thermo-<br />
Dynamic<br />
Steam Trap<br />
Float &<br />
Thermostatic<br />
Steam Trap<br />
Total back pressure is the height (H)<br />
in feet x .0433 plus PSIG in return<br />
line, plus downstream piping friction<br />
pressure drop in PSI (Determined by<br />
the maximum instantaneous discharge<br />
rate of the selected pump.)<br />
Reboiler<br />
Vented<br />
Receiver<br />
Strainer<br />
Condensate Return<br />
Filling<br />
Head<br />
Vent to<br />
Atmosphere<br />
Return Line<br />
Pressure Gauge<br />
Pressure<br />
Powered<br />
Pump<br />
Balanced<br />
Pressure<br />
Thermostatic<br />
Air Vent<br />
Drain to<br />
Safe<br />
Place<br />
Float &<br />
Thermostatic<br />
Steam Trap<br />
Motive<br />
S<strong>up</strong>ply<br />
Strainer<br />
Thermo-<br />
Dynamic<br />
Steam Trap<br />
Condensate<br />
Return Main<br />
Total<br />
Lift<br />
“H”