Elevated or<br />

Pressurized<br />

Return<br />

P 2<br />

Steam<br />

S<strong>up</strong>ply<br />

Steam Trap Station<br />

Float &<br />

Thermostatic<br />

Steam Trap<br />

Thermo-<br />

Dynamic<br />

Steam Trap<br />

Spira-tec<br />

Loss Detector<br />

Strainer<br />

Spira-tec<br />

Loss Detector<br />

See Fig. II-35A for<br />

the preassembled<br />

Process Condensate<br />

Removal Module<br />

Strainer<br />

Moisture<br />

Separator<br />

Motive<br />

Steam S<strong>up</strong>ply<br />

Float &<br />

Thermostatic<br />

Steam Trap<br />

Drain to<br />

Safe<br />

Place<br />

Pressure<br />

Powered<br />

Pump<br />

Figure II-34A<br />

Condensate Recovery Module<br />

A preassembled modular pumping system can be used<br />

to recover and reuse the condensate.<br />

Strainer<br />

Thermo<br />

-static<br />

Air Vent<br />

Reservoir Pipe<br />

Pneumatic<br />

Control<br />

Valve<br />

Heat Exchanger<br />

Liquid Expansion<br />

Steam Trap<br />

Drain<br />

P 1<br />

Control<br />

Signal<br />

Controller<br />

S<strong>up</strong>ply<br />

Air<br />

Note: To prevent<br />

overheating,<br />

the scensor<br />

must not see<br />

a “dead” flow.<br />

Sensor<br />

Hot<br />

Flow<br />

Cool<br />

Return<br />

Figure II-35<br />

Draining Equipment to Pressurized<br />

Return with Closed Loop<br />

Pump/Trap Drainage System<br />

P1 exceeds P2 except when partial<br />

loads “stall” the exchanger. With this<br />

hook <strong>up</strong>, the reservoir pipe is always<br />

connected to, and at the same pressure<br />

as, the heat exchanger steam<br />

space. Condensate drains to it freely.<br />

The pump body is connected in the<br />

same way, except during the discharge<br />

stroke when the inlet check valve and<br />

the exhaust valve are closed. After discharge,<br />

the residual steam in the pump<br />

body is exhausted to the heater and its<br />

latent heat can then be recovered.<br />

Steam trap functions at full load and<br />

Thermoton drains at shutdown.<br />

Figure II-35A<br />

Process Condensate Removal Module<br />

A preassembled modular will remove condensate from the<br />

heat exchanger under all operating conditions.<br />

HOOK-UP DIAGRAMS<br />

101