Consideration <strong>Description</strong><br />

Lightning The user is protected under the UL codes against over voltage<br />

in the system. However, the system itself is susceptible to over<br />

voltage, such as lightning, depending on the configuration. The<br />

loss of service because of an over voltage condition can result<br />

in the loss of one or more of the following elements:<br />

● Terminal loss<br />

Power requirements<br />

● Port loss<br />

● Media Module loss<br />

Acoustic noise generated 50 dBA maximum<br />

Electromagnetic<br />

compatibility st<strong>and</strong>ards<br />

● Power supply within the G700<br />

Con<strong>for</strong>ms to the electromagnetic compatibility st<strong>and</strong>ards <strong>for</strong><br />

the countries in which it operates.<br />

European union st<strong>and</strong>ards Approved to Safety St<strong>and</strong>ard EN60950.<br />

Air flow with a single fan<br />

failure<br />

Air flow with the power<br />

supply fan failure<br />

In front of the backplane, airflow is 264 linear feet per minute<br />

average. If a fan fails in front of the backplane, airflow<br />

becomes 174 lfpm average, with a range from 42 to 340 lfpm.<br />

Minimal air flow at power supply if power supply fan fails.<br />

The power supply complies with FCC Part 15, Subpart B Class B <strong>and</strong> EN55022 Class B<br />

requirements <strong>for</strong> conducted <strong>and</strong> radiated electromagnetic interferences (EMI). You can use the<br />

power supply in single or multiple G700 Media Gateways. The power supply must allow the<br />

system to comply with Class B requirements with +6 dB of margin.<br />

This power unit can be a single power supply or multiple modules that are sized <strong>and</strong> scalable <strong>for</strong><br />

the load. The <strong>Avaya</strong> Ethernet switches have a power unit that meets the 802.3 AF st<strong>and</strong>ard <strong>and</strong><br />

provides remote power <strong>for</strong> the telephone. The power supply meets all applicable global<br />

st<strong>and</strong>ards <strong>for</strong> safety, immunity, <strong>and</strong> emissions, <strong>and</strong> is verified by in-country testing.<br />