05.03.2013 Views

Hardware Description and Reference for Avaya ... - Avaya Support

Hardware Description and Reference for Avaya ... - Avaya Support

Hardware Description and Reference for Avaya ... - Avaya Support

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

● Framing at 12 kbps<br />

● Maintenance at 4 kbps<br />

The TN2198 supports a maximum of 24 telephones or data modules.<br />

The TN2198 is not offered as a BRI Tie Trunk.<br />

TN2199 central office trunk (3-wire, 4 ports)<br />

TN2199 central office trunk (3-wire, 4 ports)<br />

The TN2199 central office (CO) trunk circuit pack is designed <strong>for</strong> use in Russia.<br />

The TN2199 is a 4-port, 3-wire, loop-start trunk circuit pack that can be used as a:<br />

● DID trunk<br />

● Two-way, one-way incoming, or one-way outgoing CO trunk<br />

The TN2199 combines the functionality of a DID trunk <strong>and</strong> a one-way outgoing CO trunk (DIOD<br />

trunk). To accomplish MF shuttle signaling, the TN2199 circuit pack must be combined with a<br />

TN744D Call Classifier circuit pack.<br />

The TN2199 circuit pack supports incoming automatic number identification (ANI).<br />

TN2202 ring generator<br />

The TN2202 ring generator circuit pack is designed <strong>for</strong> use in France.<br />

The TN2202 ring generator circuit pack supplies 50-Hz ringing power. The TN2202 supplies<br />

balanced ringing to telephones that connect to the TN2183/TN2215 multicountry analog line<br />

circuit pack. A modified backplane allows this balanced ringing. The telephones must be<br />

administered <strong>for</strong> France analog transmission.<br />

The TN2202 plugs into the power unit slot <strong>and</strong> is required <strong>for</strong> each carrier that contains analog<br />

lines requiring 50-Hz ringing. A 1-lead modification is required in a carrier backplane that uses<br />

the TN2202. This modification is required <strong>for</strong> all products that are made <strong>for</strong> France. The TN2202<br />

can:<br />

● produce two symmetric voltages (usually 28 V RMS) with respect to ground,<br />

● take –48 VDC, –5 VDC, <strong>and</strong> ground from the backplane, <strong>and</strong><br />

● generate 2 × 28 V RMS with added –48 VDC.<br />

For CMC1 systems, this circuit pack is not needed.<br />

Issue 6 February 2007 251

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!