Circuit packs, channel service units, <strong>and</strong> power supplies<br />

IPSI support <strong>for</strong> system maintenance<br />

A TN2312BP IPSI placed in a G650 with a carrier address set to A acts as the serial bus master.<br />

A TN2312BP IPSI can only be placed in a G650 with a carrier address set to A or B. Only a<br />

TN2312BP IPSI in a G650 with a carrier address set to A can function as an serial bus master.<br />

The TN2312BP IPSI also provides environmental maintenance <strong>for</strong> the G650. This includes:<br />

● Power supply, cabinet, <strong>and</strong> ring generator maintenance<br />

● External device alarm detection<br />

● Emergency transfer control<br />

● Customer-provided alarm device control<br />

The TN2312BP IPSI <strong>and</strong> the 655A power supply provide the following in<strong>for</strong>mation to the G650:<br />

● Environment maintenance<br />

- Inlet temperature of the G650<br />

- Exhaust temperature of G650<br />

- Hot Spot temperature status<br />

- Voltage, +5, -5, or -48<br />

- Fan speed<br />

- Fan alarm<br />

- Ring status<br />

- Ring control<br />

- Ringer Setting<br />

- Ring Detection<br />

- Input Power, AC or DC<br />

● External device alarm detection<br />

The external device alarm detection uses two external leads. External devices such as an<br />

uninterruptible power supply (UPS) or voice messaging system can use these leads to<br />

generate alarms. The external device uses the <strong>Avaya</strong> Communication Manager alarm<br />

reporting capability. Ground potential on either of these leads results in an alarm being<br />

generated. You can administer the alarm level, product ID, alternate name, <strong>and</strong> alarm<br />

description <strong>for</strong> each lead. The alarm levels are major, minor, <strong>and</strong> warning.<br />

● Emergency transfer control<br />

Emergency transfer control provides -48 VDC to operate an external emergency transfer<br />

panel. The Communication Manager controls the state of the emergency transfer. When the<br />

emergency transfer is set to other than auto, an alarm is generated.<br />

260 <strong>Hardware</strong> <strong>Description</strong> <strong>and</strong> <strong>Reference</strong> <strong>for</strong> <strong>Avaya</strong> Communication Manager