For in<strong>for</strong>mation on port network connectivity, see Administration <strong>for</strong> Network Connectivity <strong>for</strong><br />

<strong>Avaya</strong> Communication Manager, 555-233-504.<br />

Reliability when sending voice bearer over direct-connect, ATM, or CSS<br />

The S8720/S8710 Media Server supports the following reliability configurations with<br />

direct-connect, CSS, or ATM port network configurations:<br />

● St<strong>and</strong>ard reliability<br />

St<strong>and</strong>ard reliability includes duplicated S8700-series servers. When the active server fails,<br />

an automatic interchange occurs, <strong>and</strong> st<strong>and</strong>by server assumes call processing control.<br />

During the interchange, most IP phone calls continue. All other calls are dropped.<br />

● High reliability<br />

High reliability includes duplicated control networks <strong>and</strong> duplicated servers. The servers are<br />

each connected to two Ethernet switches. These Ethernet switches are normally each<br />

connected to the IPSI-connected port networks. Two separateTN2312BP IPSI circuit packs<br />

in each IPSI-connected PN is connected to one of the Ethernet switches. If the control<br />

connection through one Ethernet switch fails or the connection to one IPSI fails, the other<br />

Ethernet switch <strong>and</strong> IPSI complete the connection to the server.<br />

● Critical reliability<br />

Critical reliability includes duplicated servers, duplicated control networks, <strong>and</strong> duplicated<br />

bearer networks. In addition to the control duplication of the high reliability option, fiber<br />

connections between port networks are duplicated. For direct-connect configurations,<br />

TN570 Expansion Interface connections are duplicated. For CSS configurations, each CSS<br />

node has two switch node carriers, such that switch node interfaces are duplicated. For<br />

ATM configurations, the ATM switches are duplicated.<br />

Multiple reliabilities among PNs<br />

The port networks that are connected together with fiber in direct-connect, CSS, <strong>and</strong> ATM<br />

configurations must all share the same reliability level. However, when IP-PNC port networks<br />

are added to a configuration that includes fiber-PNC port networks, the IP-PNC port networks<br />

may have a different reliability level. Additionally, IP-PNC port networks in the same<br />

Communication Manager configuration can have different reliability levels.<br />

Survivability<br />

In addition to the high reliability of the duplicated S8720 or S8710 Media Servers, recovery<br />

capability is embedded in the Communication Manager software that resides on the S8720 or<br />

S8710 Media Server. Thus, the S8720 or S8710 Media Server can use the following recovery<br />

options:<br />

● S8700-series Media Server as an Enterprise Survivable Server on page 85<br />

● S8300 Media Server in an LSP mode on page 86<br />