Components<br />

Auxiliary cabinet<br />

MCC1 Media Gateway<br />

The auxiliary cabinet contains the hardware to install optional equipment. The cabinet allows<br />

carrier, rack (width of 23 in. [58.4 cm]), <strong>and</strong> panel types of mounting. An auxiliary cabinet<br />

contains the following components:<br />

● A fuse panel (J58889AB) that distributes -48 VDC to fused cabinet circuits<br />

● An AC power receptacle strip that provides switched <strong>and</strong> unswitched 120-VAC receptacles<br />

● A DC connector block <strong>for</strong> cabinets powered by:<br />

- An external DC source<br />

- An AC-to-DC converter that:<br />

● Accepts AC power from a switched outlet of an AC power strip<br />

● Sends converted DC power onto the required DC connector block<br />

Processor Port network cabinet <strong>for</strong> DEFINITY Server SI<br />

A PPN cabinet <strong>for</strong> DEFINITY Server SI contains the following carriers:<br />

● One to four port carriers (J58890BB)<br />

● One control carrier (J58890AH) in the A position<br />

● One duplicated control carrier (J58890AJ), in a high reliability or critical reliability<br />

configuration, in the B position<br />

Port network cabinet <strong>for</strong> the S8700-series Media<br />

Server<br />

A PN cabinet <strong>for</strong> the S8700-series Media Server contains the following components:<br />

● One to four port carriers (J58890BB)<br />

● An ATM Interface circuit pack in a configuration with Asynchronous Transfer Mode (ATM)<br />

● Switch node (SN) carrier (J58890SA) in a configuration with center stage switch (CSS)<br />

- Minimum of one SN carrier in a st<strong>and</strong>ard reliability or a duplicated control (high reliability)<br />

network configuration with a CSS<br />

- 2 SN carriers in a duplicated bearer (critical reliability) configuration<br />

See Typical PN cabinet <strong>for</strong> all server models on page 200 <strong>for</strong> an example of a typical PN<br />

cabinet.<br />

Issue 6 February 2007 199