Carriers<br />

Circuit packs labeled with gray <strong>and</strong> white latches have replaced the purple-colored <strong>and</strong> the<br />

white-colored circuit packs. A label with gray indicates a slot <strong>for</strong> a port circuit pack. A label with<br />

white indicates a slot <strong>for</strong> a control circuit pack.<br />

A 25-pair connector on the rear panel of the carrier connects to each port slot in the following<br />

carriers:<br />

● a port carrier<br />

● an expansion control carrier<br />

● a control carrier<br />

A cable attaches to each connector <strong>and</strong> routes to the cross-connect field.<br />

The following blank faceplates cover empty carrier slots to ensure proper cooling:<br />

● 158J (4 in/9.2 cm) covers the area to the left of slot 1 in port cabinets<br />

● 158P (0.75 in/1.9 cm) covers any unused slot.<br />

● 158N (0.50 in/1.27 cm) is used with the LAN Gateway in DEFINITY AUDIX Release 3 <strong>and</strong><br />

CallVisor ASAI installations.<br />

● 158G (0.25 in/0.63 cm) is used with the TN755 or the TN2202 circuit pack.<br />

This section describes the carriers that the SCC1 Media Gateway can use.<br />

Basic control cabinet <strong>for</strong> a DEFINITY Server SI<br />

The basic control cabinet is in the PPN only <strong>and</strong> is used only by DEFINITY Server SI. This<br />

cabinet contains ports, a control complex to per<strong>for</strong>m call processing, <strong>and</strong> an interface to an<br />

optional duplicated control cabinet. The basic control cabinet also interfaces to an optional<br />

Stratum-3 clock.<br />

The basic control cabinet has dedicated white-colored slots that contain specific control circuit<br />

packs. Dual-colored slots can contain any port circuit pack or a designated white circuit pack,<br />

such as a power unit like the TN755 or TN2202. AC or DC input power supplies provide power<br />

to the carrier. The following figure shows an example of the basic control cabinet.<br />