Circuit packs, channel service units, <strong>and</strong> power supplies<br />

EPNs that are within 22 miles (35.4 kilometers) of the PPN can be coupled using single-mode<br />

fiber-optic cable. You must use a DS1 converter complex to connect an EPN when the distance<br />

between the PPN <strong>and</strong> the EPN exceeds a certain distance or private right-of-way is unavailable.<br />

The maximum distances are 5 miles (8 kilometers) <strong>for</strong> multimode cable, or 22 miles (35.4 km)<br />

<strong>for</strong> single-mode cable. One DS1 circuit pack is placed on each end of the DS1 converter<br />

complex.<br />

The TN1654 DS1 converter requires a set of Y-cables to connect to a TN570B Expansion<br />

Interface circuit pack.<br />

TN2138 central office trunk (8 ports)<br />

Note:<br />

Note: This circuit pack is no longer sold.<br />

The TN2138 central office (CO) trunk circuit pack provides eight analog loop start CO trunk<br />

ports <strong>for</strong> Italy. Each port has a tip <strong>and</strong> ring signal lead. The TN2138 has 50-Hz, 12-kHz, <strong>and</strong><br />

16-kHz periodic pulse metering (PPM).<br />

TN2139 direct inward dialing trunk(8 ports)<br />

Note:<br />

Note: This circuit pack is no longer sold.<br />

The TN2139 direct inward dialing trunk <strong>for</strong> Italy provides eight analog direct inward dialing (DID)<br />

trunk ports <strong>for</strong> analog DID signaling. Each of the eight ports has a tip <strong>and</strong> ring signal lead.<br />

TN2140B tie trunk (4-wire, 4 ports)<br />

The TN2140B tie trunk is used in Hungary <strong>and</strong> Italy. The TN2140B provides four ports <strong>for</strong> 4-wire<br />

E&M lead signaling tie trunks. The TN2140 provides continuous E&M signaling <strong>and</strong><br />

discontinuous E&M signaling. The TN2140 also provides administrable A- <strong>and</strong> µ-Law<br />

comp<strong>and</strong>ing <strong>and</strong> st<strong>and</strong>ard Type 1 <strong>and</strong> Type 5 signaling. The TN2140B is required <strong>for</strong> Hungary.<br />

246 <strong>Hardware</strong> <strong>Description</strong> <strong>and</strong> <strong>Reference</strong> <strong>for</strong> <strong>Avaya</strong> Communication Manager