Duplicated control cabinet <strong>for</strong> a DEFINITY<br />

Server SI<br />

The optional duplicated control cabinet resides only in the PPN <strong>for</strong> the DEFINITY Server SI. A<br />

duplicated control cabinet contains ports <strong>and</strong> a duplicated control complex.<br />

A duplicated control cabinet has dedicated white-colored slots <strong>for</strong> designated control circuit<br />

packs. A port circuit-pack slot can contain any port circuit pack.<br />

An AC or a DC power supply resides in the right side of the cabinet. The cabinet contains a<br />

duplication interface circuit pack in slot DUPN INTFC. The following figure shows an example of<br />

a duplicated control cabinet.<br />

Figure 50: Duplicated control cabinet (J58890M)<br />

B<br />

AUTO<br />

A<br />

103577450<br />

TN792 DUPL INTERFACE<br />

S<br />

P<br />

E<br />

OVERIDE<br />

ALARMS<br />

MAJ<br />

MIN<br />

WRN<br />

ACK<br />

Lucent<br />

98DR07125243<br />

T<br />

N<br />

7<br />

9<br />

2<br />

EMER TR<br />

ON<br />

AUTO<br />

OFF<br />

T<br />

N<br />

2<br />

4<br />

0<br />

4<br />

The following table describes the connectors in the duplicated control cabinet.<br />

Connector Function<br />

B<br />

l<br />

a<br />

n<br />

k<br />

1<br />

5<br />

8<br />

P<br />

B<br />

l<br />

a<br />

n<br />

k<br />

C<br />

A<br />

R<br />

D<br />

I<br />

N<br />

U<br />

S<br />

E<br />

T<br />

N<br />

2<br />

4<br />

0<br />

1<br />

B<br />

l<br />

a<br />

n<br />

k<br />

T<br />

N<br />

2<br />

1<br />

8<br />

2<br />

T<br />

N<br />

5<br />

7<br />

0<br />

01 to 16 (A01 to A16) 25-pair connectors that provide interfaces between port circuit packs<br />

<strong>and</strong> the cross-connect field or a fiber optic transceiver<br />

TERMINAL Can connect to the processor circuit pack in the duplicated control<br />

cabinet if the duplication interface circuit pack fails in the control<br />

carrier.<br />

194 <strong>Hardware</strong> <strong>Description</strong> <strong>and</strong> <strong>Reference</strong> <strong>for</strong> <strong>Avaya</strong> Communication Manager<br />

T<br />

N<br />

5<br />

7<br />

0<br />

BBI<br />

LINK<br />

TRMT<br />

RCV<br />

T<br />

N<br />

7<br />

9<br />

9<br />

T<br />

N<br />

7<br />

5<br />

5<br />

ccdfr8m KLC 021205