See the following table <strong>for</strong> power source in<strong>for</strong>mation.<br />

Chassis style <strong>and</strong><br />

power-distribution unit<br />

<strong>Avaya</strong> G650 Media Gateway<br />

See Table 26: Circuit breakers <strong>for</strong> AC-powered chassis on page 181 <strong>for</strong> circuit breaker<br />

in<strong>for</strong>mation <strong>for</strong> AC-powered chassis.<br />

Dimensions<br />

● AC or DC power<br />

supply. Apparatus<br />

Code 655A<br />

● A 655A power<br />

supply is required<br />

in slot 0.<br />

● A 655A power<br />

supply is optional<br />

in slot 15.<br />

The G650 Media Gateway has the following dimensions:<br />

● 14h x 22d x 19w (inches)<br />

● 36h x 56d x 48w (centimeters)<br />

● height in rack: 8 U<br />

Power source options Power input receptacles<br />

● Single phase 120<br />

VAC with neutral<br />

wire<br />

● Single phase 240<br />

VAC with neutral<br />

wire<br />

● -48VDC<br />

Table 26: Circuit breakers <strong>for</strong> AC-powered chassis<br />

● 120 VAC, 60 Hz NEMA 5-15R<br />

● 240 VAC, 50 Hz IEC 320<br />

● When you instal G650s in<br />

Japan, use country specific<br />

receptacles <strong>for</strong> 100 <strong>and</strong> 200<br />

VAC, 50/60 Hz.<br />

● When you instal G650s in<br />

Mexico, use country specific<br />

receptacles <strong>for</strong> 127 VAC.<br />

Chassis type Circuit breaker size<br />

Rack mount chassis (120 VAC) 60 Hz 15 A<br />

Rack mount chassis (240 VAC) 50 Hz 10 A<br />

● weight: 35 - 39 pounds or 16 - 18 kilograms<br />

The G650 requires 12 inches, or 30 centimeters, of clearance in the rear <strong>and</strong> 18 inches, or 45<br />

centimeters of clearance in the front. This clearance allows <strong>for</strong> adequate ventilation <strong>and</strong><br />

con<strong>for</strong>ms with st<strong>and</strong>ards <strong>for</strong> the EIA3 10D data rack. In a multiple G650 configuration, the<br />

G650s are placed in a rack without any space between them. If the G650s are not correctly<br />

placed in the rack, the TDM/LAN cables cannot connect them.<br />

Issue 6 February 2007 181