Polycom DMA 7000 System Operations Guide
Polycom DMA 7000 System Operations Guide
Polycom DMA 7000 System Operations Guide
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Signaling Configuration<br />
Server Settings<br />
The following table describes the fields in the Signaling Configuration screen.<br />
Table 8-4 Fields in the Signaling Configuration screen<br />
Field Description<br />
Signaling status Status of signaling module. Ready to receive calls if<br />
registered with gatekeeper, Ready to receive IP-only<br />
calls if not.<br />
Use gatekeeper Check to enable gatekeeper fields.<br />
Status Gatekeeper registration status.<br />
Primary gatekeeper IP<br />
address or host name<br />
Alternate gatekeeper IP<br />
address or host name<br />
IP address or host name of gatekeeper. Required.<br />
IP address or host name of the secondary or backup<br />
gatekeeper. Optional.<br />
Used only when the primary is not available during<br />
startup or when the alternate designated by the primary<br />
gatekeeper is not available.<br />
H.323 prefix (E.164) E.164 dial string prefix for calling the system. Required.<br />
Must be unique among the gatekeeper’s devices and<br />
services.<br />
If the Simplified Dialing service is enabled and registers<br />
with a prefix of 9 (the default), you can’t use 90-99. The<br />
gatekeeper recognizes the 9 as a known prefix and<br />
ignores the second digit.<br />
To configure signaling<br />
1 On the gatekeeper, verify that the H.323 prefix you want to use is<br />
available.<br />
If you register with a prefix that’s already in use, you receive no warning<br />
that something is wrong, but calls to the system will fail.<br />
2 On the <strong>Polycom</strong> <strong>DMA</strong> system, go to <strong>System</strong> Setup > Server Settings ><br />
Signaling Configuration.<br />
3 Check Use gatekeeper.<br />
4 Enter the IP address or host name for the primary gatekeeper.<br />
5 Enter the IP address or host name for the alternate gatekeeper (optional).<br />
6 Enter the H.323 prefix to be used to reach the <strong>DMA</strong> system.<br />
Users dial this prefix followed by the conference room number.<br />
7 Click Update.<br />
A dialog box informs you that the configuration has been updated.<br />
<strong>Polycom</strong>, Inc. 8–7