12 Table 5 Environmental Specifications Specification Description Altitude 1000 m (3300 ft) maximum without derating Storage Temperature –40…70 °C (–40…158 °F) Atmosphere Important: Drive must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas, vapors or dust. If the drive is not going to be installed for a period of time, it must be stored in an area where it will not be exposed to a corrosive atmosphere. Relative Humidity 5…95% non-condensing Shock - Operating Frame 2…6: 15 g peak for 11 ms duration (±1.0 ms) Frame 7: 10 g peak for 11 ms duration (±1.0 ms) Shock - Packaged for Shipment Frame 2: 381 mm (15 in.) drop height Frame 3…4: 330 mm (13 in.) drop height Frame 5: 305 mm (12 in.) drop height Frame 6…7: Meets International Safe Transit Association (ISTA) test procedure 2B Vibration - Operating Frame 2: 1.000 mm (0.040 in.) displacement, 2 g peak Frame 3…5: 1.000 mm (0.040 in.) displacement, 1.5 g peak Frame 6…7: 1.000 mm (0.040 in.) displacement, 1 g peak Vibration - Packaged for Shipment Sinusoidal Loose Load: Random Secured: Surrounding Environment Pollution Degree (1) Pollution Degree 1 & 2: Pollution Degree 3 & 4: Table 6 Pollution Degree Ratings According to EN 61800-5-1 Pollution Degree Description 1 No pollution or only dry, non-conductive pollution occurs. The pollution has no influence. 2 Normally, only non-conductive pollution occurs. Occasionally, however, a temporary conductivity caused by condensation is to be expected, when the drive is out of operation. 3 Conductive pollution or dry non-conductive pollution occurs, which becomes conductive due to condensation, which is to be expected. 4 The pollution generates persistent conductivity caused, for example by conductive dust or rain or snow. <strong>PowerFlex</strong> 750-Series <strong>Install</strong>ation Instructions – Publication 750-IN001C-EN-P – September 2009 Frame 2…5: 20.0 mm (0.8 in.) peak to peak, 2…5.186 Hz; 1.1 g peak from 5.186…20 Hz Frame 6…7: Meets ISTA 2B packaging standards Frame 2…5: Frequency (Hz) PSD (g 2 /Hz) 1 0.00005 4 0.01 16 0.01 40 0.001 80 0.001 200 0.00001 Frame 6…7 Meets International Safe Transit Association (ISTA) test procedure 2B All enclosures acceptable. Enclosure that meets or exceeds IP54, NEMA/UL Type 12 required. (1) Refer to Table 6 on page 12 for descriptions of each pollution degree rating.
Table 7 Drive Enclosure Ratings Enclosure Type Front Side Rating Back Side/Heat Sink Rating (Cat. No. <strong>Install</strong>ed Pollution Frames Position 6) Accessory Kit Enclosure Type Degree Enclosure Type 2, 3, 4, 5 N None IP20 1, 2 IP20 NEMA/UL Open Type NEMA/UL Open Type NEMA Type 1 IP20 1, 2 IP20 NEMA/UL Type 1 NEMA/UL Type 1 Flange IP20 1, 2 IP20 NEMA/UL Type 1 NEMA/UL Type 1 F None IP20 1, 2 IP66 NEMA/UL Open Type NEMA/UL Type 4X G None IP54 1, 2, 3, 4 IP54 NEMA/UL Type 12 NEMA/UL Type 12 6, 7 N None IP00 1, 2 IP00 NEMA/UL Open Type NEMA/UL Open Type Kit NEMA Type 1 IP20 1, 2 IP20 NEMA/UL Type 1 NEMA/UL Type 1 NEMA Type 4X IP00 1, 2 IP66 Flange NEMA/UL Open Type NEMA/UL Type 4X G None IP54 1, 2, 3, 4 IP54 NEMA/UL Type 12 NEMA/UL Type 12 Pollution Degree 1, 2 <strong>PowerFlex</strong> 750-Series <strong>Install</strong>ation Instructions – Publication 750-IN001C-EN-P – September 2009 1, 2 1, 2 1, 2, 3, 4 1, 2, 3, 4 1, 2 1, 2 1, 2, 3, 4 1, 2, 3, 4 13