50<br />

Drive, Fuse & Circuit Breaker Ratings<br />

Table 19 and Table 20 provide drive ratings (including continuous, 1 minute<br />

and 3 second) and recommended AC line input fuse and circuit breaker<br />

information. Sizes listed are the recommended sizes based on 40 degree C<br />

and the U.S N.E.C. Other country, state or local codes may require different<br />

ratings.<br />

Refer to Table 18 which describes input device requirements based on<br />

physical installation choice.<br />

Table 18 Input Device Requirements<br />

Enclosure<br />

UL Certification Not<br />

Frames Catalog Code Enclosure Type <strong>Install</strong>ation Type UL Certification Required Required<br />

N<br />

F<br />

IP20<br />

NEMA/UL Open Type<br />

Flange<br />

<strong>Install</strong>ed in a non-ventilated<br />

cabinet. Heat sink is inside or<br />

outside of cabinet.<br />

All devices in Table 19 are<br />

acceptable.<br />

2, 3, 4, 5 N<br />

IP20<br />

NEMA/UL Open Type<br />

<strong>Install</strong>ed outside of cabinet<br />

using NEMA Type 1 kit or in a<br />

Devices in Table 19 excluding<br />

time delay fuses and maximum<br />

F Flange<br />

ventilated cabinet.<br />

value for non-time delay fuses.<br />

G<br />

IP54<br />

NEMA/UL Type 12<br />

<strong>Install</strong>ed inside or outside of<br />

any cabinet.<br />

<strong>Install</strong>ed in any cabinet.<br />

All devices in Table 19 are<br />

acceptable.<br />

All devices in Table 19 are<br />

acceptable.<br />

6, 7<br />

N<br />

IP00<br />

NEMA/UL Open Type<br />

Heat sink is inside or outside<br />

of cabinet.<br />

<strong>Install</strong>ed outside of cabinet<br />

using NEMA Type 1 kit.<br />

All devices in Table 19 are<br />

acceptable.<br />

G<br />

IP54<br />

NEMA/UL Type 12<br />

<strong>Install</strong>ed inside or outside of<br />

any cabinet.<br />

All devices in Table 19 are<br />

acceptable.<br />

Fusing<br />

For optimum protection, semiconductor type fusing is recommended.<br />

For general purpose fusing, refer to the recommended types listed below.<br />

IEC – BS88 (British Standard) Parts 1 & 2 (1) , EN60269-1, Parts 1 & 2,<br />

type gG or equivalent should be used.<br />

UL – UL Class CC, T, RK1 or J should be used.<br />

(1) Typical designations include, but may not be limited to the following; Parts 1 & 2: AC, AD, BC, BD, CD, DD ED,<br />

EFS, EF, FF, FG, GF, GG, GH.<br />