I/O Wiring Examples<br />
51 Anlg In0 Hi Analog Inputs 113 RO1 ElapsedLife (2)<br />
Predictive Main<br />
52 Anlg In0 Lo Analog Inputs 114 RO1 RemainLife (2)<br />
Predictive Main<br />
53 Anlg In0 LssActn Analog Inputs 115 RO1 LifeEvntLvl (2)<br />
Predictive Main<br />
54 Anlg In0 Raw Val Analog Inputs 116 RO1 LifeEvntActn (2)<br />
Number Parameter Name Group Number Parameter Name Group<br />
Predictive Main<br />
55 Anlg In0 Filt Gn Analog Inputs<br />
(1) Parameter applies to models C-2R and C-1R2T only.<br />
(2) Parameter applies to models C-2R and D-2R only.<br />
(3) Parameter applies to model C-1R2T only.<br />
753 Main Control Board TB1 Wiring Examples<br />
Input/Output Connection Example Required Parameter Changes<br />
Potentiometer Unipolar<br />
Speed Reference<br />
10k Ohm Pot.<br />
Recommended<br />
(2k Ohm Minimum)<br />
Analog Input Bipolar<br />
Speed Reference<br />
±10V Input<br />
Analog Voltage Input<br />
Unipolar Speed<br />
Reference<br />
0 to +10V Input<br />
J4<br />
3 1<br />
4 2<br />
Common<br />
+<br />
Common<br />
+<br />
10VC<br />
+10V<br />
Ai0–<br />
Ai0+<br />
Ai0–<br />
Ai0+<br />
Ai0–<br />
Ai0+<br />
Set Direction Mode<br />
Port 0: P308 [Direction Mode] = 0 “Unipolar”<br />
Set Selection<br />
Port 0: P545 [Spd Ref A Sel] = Port 0: P260 [Anlg In0 Value]<br />
Adjust Scaling<br />
Port 0: P261 [Anlg In0 Hi] = 10 Volt<br />
Port 0: P262 [Anlg In0 Lo] = 0 Volt<br />
Port 0: P547 [Spd Ref A AnlgHi] = 60 Hz<br />
Port 0: P548 [Spd Ref A AnlgLo] = 0 Hz<br />
View Results<br />
Port 0: P260 [Anlg In0 Value]<br />
Port 0: P592 [Selected Spd Ref]<br />
Set Direction Mode<br />
Port 0: P308 [Direction Mode] = 1 “Bipolar”<br />
Set Selection<br />
Port 0: P545 [Spd Ref A Sel] = Port 0: P260 [Anlg In0 Value]<br />
Adjust Scaling<br />
Port 0: P261 [Anlg In0 Hi] = +10 Volt<br />
Port 0: P262 [Anlg In0 Lo] = -10 Volt<br />
Port 0: P547 [Spd Ref A AnlgHi] = +60 Hz<br />
Port 0: P548 [Spd Ref A AnlgLo] = -60 Hz<br />
View Results<br />
Port 0: P260 [Anlg In0 Value]<br />
Port 0: P592 [Selected Spd Ref]<br />
Set Direction Mode<br />
Port 0: P308 [Direction Mode] = 0 “Unipolar”<br />
Set Selection<br />
Port 0: P545 [Spd Ref A Sel] = Port 0: P260 [Anlg In0 Value]<br />
Adjust Scaling<br />
Port 0: P261 [Anlg In0 Hi] = 10 Volt<br />
Port 0: P262 [Anlg In0 Lo] = 0 Volt<br />
Port 0: P547 [Spd Ref A AnlgHi] = 60 Hz<br />
Port 0: P548 [Spd Ref A AnlgLo] = 0 Hz<br />
View Results<br />
Port 0: P260 [Anlg In0 Value]<br />
Port 0: P592 [Selected Spd Ref]<br />