6 Service and Maintenance<br />

CONVECTRON<br />

DISPLAY BEGIN<br />

READ PRESSURE<br />

DISPLAY<br />

SELECT CORRECT<br />

UNITS<br />

REPLACE GAUGE<br />

REPLACE CABLE<br />

NO YES YES<br />

IS<br />

PRESSURE<br />

DISPLAY AS<br />

EXPECTED?<br />

NO<br />

CHECK DISPLAY<br />

UNITS SWITCH<br />

IS<br />

SWITCH<br />

SET<br />

CORRECTLY?<br />

YES<br />

CHECK<br />

CONVECTRON<br />

GAUGE<br />

IS<br />

GAUGE<br />

DAMAGED OR NO<br />

CONTAMINATED?<br />

CHECK<br />

CONVECTRON<br />

GAUGE CABLE<br />

IS<br />

CABLE<br />

DAMAGED?<br />

NO<br />

YES<br />

CHECK<br />

CABLE LENGTH<br />

IS<br />

CABLE<br />

LONGER THAN<br />

50 FEET?<br />

NO<br />

CHECK<br />

VACUUM RANGE<br />

IS<br />

RANGE IN<br />

10 -4 DECADE?<br />

NO<br />

CALL FACTORY<br />

YES<br />

YES<br />

CONVECTRON<br />

DISPLAY FINISH<br />

RE-CALIBRATE<br />

VAC & ATM<br />

Figure 6-10<br />

Convectron Gauge Display.<br />

<strong>360</strong> RS-232<br />

IEEE 488 BEGIN<br />

SEND MESSAGE<br />

TO <strong>360</strong><br />

REPLACE CABLE<br />

CORRECT SETUP<br />

CORRECT SETUP<br />

YES YES YES<br />

DID<br />

<strong>360</strong><br />

RESPOND?<br />

NO<br />

CHECK COMPUTER<br />

INTERFACE CABLE<br />

IS<br />

CABLE<br />

DAMAGED<br />

OR WIRED<br />

INCORRECTLY?<br />

NO<br />

CHECK COMPUTER<br />

TERMINAL<br />

IS<br />

TERMINAL<br />

SET UP<br />

INCORRECTLY?<br />

NO<br />

CHECK<br />

<strong>360</strong> SETUP<br />

SWITCHES<br />

ARE<br />

SWITCHES<br />

SET<br />

INCORRECTLY?<br />

NO<br />

YES<br />

CHECK<br />

MESSAGE SYNTAX<br />

IS<br />

SYNTAX<br />

INCORRECT?<br />

NO<br />

CHECK<br />

MESSAGE VALIDITY<br />

IS<br />

MESSAGE<br />

INVALID?<br />

NO<br />

CALL FACTORY<br />

YES<br />

YES<br />

<strong>360</strong> RS-232<br />

IEEE 488 FINISH<br />

CORRECT SYNTAX<br />

MAKE MESSAGE<br />

VALID<br />

Figure 6-11<br />

RS-232/IEEE 488 Interface.<br />

<strong>Series</strong> <strong>360</strong> <strong>Stabil</strong>-<strong>Ion</strong> December, 2001<br />