Tab. A. 4. 6. Data <strong>of</strong> the <strong>DC</strong> Motor on Laboratory setup<br />

Nominal power P = 2.7 kW<br />

Nominal voltage<br />

Nominal current<br />

Nominal frequency<br />

Base speed<br />

N<br />

U = 420 V<br />

N<br />

N<br />

I = 8.4 A<br />

f<br />

Ω<br />

SN<br />

mN<br />

= 50 Hz<br />

= 1450 rpm<br />

Tab. A. 4. 7.Data <strong>of</strong> the Supply Line <strong>and</strong> <strong>AC</strong>/<strong>DC</strong>/<strong>AC</strong> <strong>Converter</strong><br />

Line voltage U<br />

L<br />

= 141 V<br />

Line frequency f<br />

L<br />

= 50 Hz<br />

<strong>DC</strong>-link voltage U =560 V<br />

Resistive load<br />

R<br />

<strong>DC</strong><br />

load<br />

= 100 or 150 Ω<br />

<strong>DC</strong>-link capacitor C =470 µF / 47 µF<br />

Tab. A. 4. 8. Date <strong>of</strong> the LCL Input Filter in laboratory setup<br />

Line side inductance L<br />

1<br />

= 590 µH<br />

<strong>Converter</strong> side ind. L = 10 mH<br />

Resistance <strong>of</strong> L<br />

1<br />

R<br />

1=0.093 Ω<br />

Resistance <strong>of</strong> L R = 0.08 Ω<br />

Filter capacitors C<br />

F<br />

= 20 µF<br />

Tab. A. 4. 9.Data <strong>of</strong> the inverter VLT 5005<br />

Nominal output power<br />

S<br />

VLTN<br />

= 5.5 kW<br />

Nominal power on the shaft <strong>of</strong> P<br />

VLTN<br />

= 3 kW<br />

the IM fed by VSI<br />

Nominal voltage<br />

U<br />

LN<br />

= 380 V<br />

Nominal input (line) current I<br />

LVLTN<br />

= 7 A<br />

Nominal output (IM) current I<br />

SVLTN<br />

= 7.2 A<br />

Dead time<br />

T<br />

D<br />

= 2 µs<br />

Efficiency 0.96 1)<br />

1) Measured using 30 m screened motor cables at rated load – 3 kW <strong>and</strong> rated frequency – 3kHz .<br />

Two inverters VLT 5005 have been connected through <strong>DC</strong>-link connectors. The<br />

arisen <strong>DC</strong>-link circuit has been modified as in Fig. A. 4. 6.<br />

153