<strong>On</strong>-Board W <strong>Module</strong> <strong>Programming</strong> <strong>and</strong> <strong>Operation</strong><br />
CTI-CRYOGENICS<br />
HELIX TECHNOLOGY CORPORATION<br />
There are three settings available to the user:<br />
• 0 - Power Fail OFF<br />
• 1 - Power Fail ON<br />
• 2 - Power Fail Cool<br />
NOTE: If Power Fail Cool is selected, <strong>and</strong> the power failure occurs while<br />
the waterpump is ON, the waterpump will only cool down if it is below the<br />
power fail recovery temperature setpoint. If the waterpump temperature is<br />
above the setpoint, the waterpump will remain OFF.<br />
POWER FAIL ON<br />
Last<br />
1 2 3<br />
MONITOR<br />
CONTROL<br />
Next<br />
4 5 6<br />
REGEN<br />
RELAYS<br />
Clear<br />
7 8 9<br />
SERVICE<br />
HELP<br />
- 0 .<br />
Enter<br />
ON-BOARD<br />
oo<br />
®<br />
Figure 3-20: Power Fail Recovery Display<br />
Power Fail Recovery Temperature<br />
The twelfth parameter of the REGEN function allows the user to establish<br />
a temperature setpoint which the <strong>On</strong>-Board Waterpump uses to decide<br />
whether to cool down, or to perform a REGEN cycle after a power failure<br />
has occurred <strong>and</strong> power is restored. Refer to Figure 3-21.<br />
130K POWER FAIL<br />
Last<br />
1 2 3<br />
MONITOR<br />
CONTROL<br />
Next<br />
4 5 6<br />
REGEN<br />
RELAYS<br />
Clear<br />
7 8 9<br />
SERVICE<br />
HELP<br />
- 0 .<br />
Enter<br />
ON-BOARD<br />
oo<br />
®<br />
Figure 3-21: Power Fail Recovery Temperature Display<br />
P/N 8040365 3-15