CTI-CRYOGENICS<br />

HELIX TECHNOLOGY CORPORATION<br />

Delay Start<br />

1. Press the REGEN key on the keypad/display. The current<br />

REGEN status is displayed.<br />

2. Press the Next key. The current delay start time value is displayed<br />

in hours.<br />

3. Press the Enter key. The current value is underlined <strong>and</strong> ready to<br />

accept a new value.<br />

4. Press the numeral keys for the desired delay time. For example: 1,<br />

5 for 1.5, or 1, 5, <strong>and</strong> 0 for 15.0. The range of values is 0 - 999.9<br />

hours.<br />

NOTE: The Clear key may be pressed if incorrect data has been entered.<br />

The <strong>On</strong>-Board module allows the user to enter the new value.<br />

5. Press the Enter key. Delay start programming is complete.<br />

6. Press the MONITOR key. The <strong>On</strong>-Board microprocessor will<br />

monitor system operation.<br />

Delay Restart<br />

1. Press the REGEN key on the keypad/display. The current<br />

REGEN status is displayed.<br />

2. Press the Next key until the current delay restart time value is<br />

displayed in hours.<br />

3. Press the Enter key. The current value is underlined <strong>and</strong> ready to<br />

accept a new value.<br />

4. Press the numeral keys for the desired delay time. For example: 1,<br />

5 for 1.5, or 1, 5, <strong>and</strong> 0 for 15.0. The range of values is 0 - 999.9<br />

hours.<br />

NOTE: The Clear key may be pressed if incorrect data has been entered.<br />

The <strong>On</strong>-Board module allows the user to enter the new value.<br />

5. Press the Enter key. Delay restart programming is complete.<br />

6. Press the MONITOR key. The <strong>On</strong>-Board microprocessor will<br />

monitor system operation.<br />

Repurge<br />

1. Press the REGEN key on the keypad/display. The current<br />

REGEN status is displayed.<br />