On-Board® W Module Programming and Operation ... - PTB Sales
On-Board® W Module Programming and Operation ... - PTB Sales
On-Board® W Module Programming and Operation ... - PTB Sales
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>On</strong>-Board W <strong>Module</strong> <strong>Programming</strong> <strong>and</strong> <strong>Operation</strong><br />
CTI-CRYOGENICS<br />
HELIX TECHNOLOGY CORPORATION<br />
Table 3-2: SERVICE Function Parameters<br />
SERVICE Parameter Default Value Range of Values<br />
Serial Number/Software Version - -<br />
Net ID 0 0 - 9<br />
Elapsed Pump Time - Hours<br />
Time Since Last Cooldown - Hours<br />
Password 0 0 - 32,767<br />
Lock Mode OFF 1 (ON)/ 0 (OFF)<br />
Parameter Lock OFF 1 (ON)/ 0 (OFF)<br />
Zero Auxiliary Thermocouple - -<br />
Zero Cryopump Thermocouple* - -<br />
First Stage Temperature 107K 107K - 320K<br />
* For appendage waterpumps only<br />
Serial Number <strong>and</strong> Software Version<br />
The first parameter of the SERVICE function allows the user to display the<br />
<strong>On</strong>-Board Waterpump serial number (SN information) <strong>and</strong> current module<br />
software version (PF information) as shown in Figure 3-26.<br />
The serial number is used to identify the waterpump. The software version<br />
number identifies the software which is running in the <strong>On</strong>-Board W<br />
<strong>Module</strong>.<br />
NOTE: Press the > key to display the entire software version number.<br />
P/N 8040365 3-29