On-Board® W Module Programming and Operation ... - PTB Sales
On-Board® W Module Programming and Operation ... - PTB Sales
On-Board® W Module Programming and Operation ... - PTB Sales
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>On</strong>-Board W <strong>Module</strong> <strong>Programming</strong> <strong>and</strong> <strong>Operation</strong><br />
CTI-CRYOGENICS<br />
HELIX TECHNOLOGY CORPORATION<br />
Table C-1: RS-232 REGEN Responses <strong>and</strong> Descriptions (Continued)<br />
REGEN Response<br />
V<br />
REGENERATION ABORTED<br />
Description<br />
Comm<strong>and</strong> e displays the reasons for regeneration abort. The<br />
messages are as follows:<br />
@ - No error<br />
A,B - WARM-UP TIMEOUT - Did not reach warm-up temperature<br />
within 150 minutes.<br />
C - COOLDOWN TIMEOUT - Did not cool down within 4 hours.<br />
E - ROR CYCLE LIMIT WAS REACHED - The pump did<br />
not pass the rate-of-rise test within the programmed cycle limit.<br />
F - MANUAL ABORT - Someone manually gave the<br />
comm<strong>and</strong> to stop regeneration.<br />
G - ROUGH VALVE TIMEOUT - Rough valve was opened<br />
for more than 1 hour without closing.<br />
W,p<br />
DELAY RESTART<br />
This countdown timer delays starting the pump for cooldown mode<br />
after it has been warmed up, roughed out, <strong>and</strong> passed the ROR test.<br />
This is a user programmed value. If the pump has no valves, the delay<br />
timer begins when the pump reaches 310K.<br />
To get the timer value in minutes, use the comm<strong>and</strong> k. Display the<br />
time in hours.<br />
X<br />
POWER FAILURE<br />
There was a power failure during the regeneration cycle <strong>and</strong> the pump<br />
will make a decision to cooldown or regenerate. This display should<br />
last for no longer than one second.<br />
Y<br />
POWER FAILURE COOLDOWN<br />
There was a power failure during regeneration but the pump is continuing<br />
to cool down. Refer to Appendix D - Power Failure<br />
Messages.<br />
P/N 8040365 C-5