Freeze Protection in Solar Only mode<br />
The SunTouch freeze protection function is active once the optional air sensor is installed and enabled<br />
(see page 8). Freeze protection is enabled whenever the outside temperature is 36º F or lower. When freezing<br />
conditions are detected by the air sensor the filter pump will be switched on and water will circulate continuously<br />
through the system. It’s important that the air sensor be permanently placed in the shade and away from windy<br />
locations. In the event of a power failure, the system will be unprotected. Recirculating water to protect your<br />
system from freezing is not recommended in climates where freezing temperatures occur frequently and last for<br />
extended periods.<br />
CAUTION If you live in a location where freezing conditions occur and there is no air sensor installed<br />
or the air sensor is not enabled, your system will be unprotected.<br />
Operating SunTouch in Pool/Spa mode (Shared Equipment)<br />
SunTouch Pool/Spa Mode<br />
Using SunTouch in the Pool/Spa mode allows pool and spa operations to be fully automated. The SunTouch<br />
menu features let you create customized schedules for your pool and spa equipment, heat temperatures and<br />
chlorination settings to switch on and off at a time and day. For maintenance and service purposes, the control<br />
panel allows manual control of all pool and spa operations.<br />
Setting up SunTouch to Operate in Pool/Spa Mode<br />
To setup SunTouch to operate in Pool/Spa mode (shared equipment):<br />
SunTouch<br />
11: 51 AM<br />
MENU<br />
Press the MENU button to<br />
access the Main Menu items<br />
▼<br />
Main Menu 8/14<br />
Advanced<br />
MENU<br />
Press the MENU button<br />
until “Advanced” displays<br />
Press the LEFT arrow button to save and exit the main menu. Note: For the Pool/Spa menu settings, see<br />
page 12.<br />
Adjusting the water temperature setting in Pool/Spa mode<br />
After setting the pool water temperature in the Heat menu (see page 14), you might occasionally need to adjust<br />
the water set point temperature. Use the (-) TEMP and (+) TEMP buttons to set the water to the desired<br />
temperature.<br />
To adjust the spa set point water temperature: Press the Spa (Up arrow) button to display the actual and set<br />
point water temperature settings. As shown below, the heat setting displayed on the left side (71° F) is the actual<br />
water temperature and on the right side the set point temperature (91° F) is displayed. The set point<br />
temperature is set in the Heat menu. Note: For Information about selecting the heat source, refer to<br />
“Selecting the Heat Source” on page 10.<br />
▼<br />
Actual<br />
temperature<br />
System Mode<br />
Pool/Spa<br />
Press the Right button to<br />
access the “System Mode”<br />
options<br />
Set<br />
temperature<br />
Press either<br />
Up or Down<br />
button and select<br />
“Pool/Spa”<br />
Press the Right<br />
button to save and<br />
exit.<br />
AIR 59°F<br />
11: 51 AM Spa<br />
button<br />
▼<br />
SPA 71°F / 91°F<br />
11: 51AM HEATER<br />
Heater<br />
activated<br />
Lower water set<br />
point temperature<br />
Raise water set<br />
point temperature<br />
SunTouch Solar, Pool and Spa Control System Installation and User’s Guide