39<br />

SunTouch Main Status Screen (Pool/Spa Mode - Single Body System)<br />

Use the SunTouch display to view the daily operations of your spa or pool. Using the UP arrow button<br />

(HI-TEMP) to manually switch the filter pump on and off and activate the heater. LOW temperature control<br />

can also be assigned to the UP arrow button. The “HIGH” and “LOW” circuit can be programmed to run at a<br />

specific time and heat setting. These circuits are assigned in the “Circuit Functions” menu (see page 26).<br />

Before using SunTouch to operate a single body system (pool only or spa only), familiarize yourself with the<br />

status screen and control buttons.<br />

HIGH 75°F / 85°F<br />

11:51AM HEATER<br />

AIR 74°F AIR: Displays the outside air<br />

11: 51AM AUX 1 temperature via the air sensor<br />

located near the pool area. This screen toggles between<br />

the “Pool” or “Spa” display (see below). To display the air<br />

temperature setting, the air sensor must be enabled<br />

(see “Advanced” menu on page 24). Degree units are<br />

displayed in either Fahrenheit or Celsius. If the top<br />

display line displays “SunTouch”, it indicates no spa or<br />

pool function is active and the air sensor is not enabled.<br />

HIGH 75°F / 85°F<br />

11:51AM HEATER<br />

Lower current set point<br />

temperature setting<br />

AIR 36°F FRZ FRZ: Indicates the air sensor is<br />

11: 51AM AUX 1 connected and enabled, and<br />

“Freeze Protection” is active (see page 26).<br />

HIGH: When the Up arrow button is<br />

pressed or this circuit is scheduled<br />

to operate, the “HIGH” filter pump circuit is switched on<br />

and current water temperature settings are displayed<br />

with the heat source being used. “HIGH” and “LOW” are<br />

displayed alternatively if both circuits are active.<br />

LOW 75°F / 85°F LOW: When the Down arrow button<br />

11:51AM HEATER is pressed or this circuit is<br />

scheduled to operate, the “LOW” filter pump circuit is<br />

switched on and current water temperature settings are<br />

displayed with the type heat source being used. “HIGH”<br />

and “LOW” are displayed alternatively if both circuits are<br />

active.<br />

®<br />

Raise current set point<br />

temperature setting<br />

HI-TEMP/LO-TEMP button: Turn<br />

heater and filter pump on or off.<br />

To activate the heater when this<br />

button is pressed, first select heat<br />

source in the “Heat 2/14” menu<br />

(page 14). To manually switch on<br />

or off the heater, use “Manual<br />

Heat” in the “Heat 2/14” menu.<br />

The heat temperature settings<br />

are displayed on the main<br />

screen. This button can also be<br />

assigned for LOW temperature<br />

control (see page 37).<br />

AUX 1: When this button is<br />

pressed, the circuit relay connected<br />

to AUX 1 is switched on<br />

and the number 1 is displayed on<br />

the lower right-side of the screen.<br />

AUX 1 can also be switched on<br />

and off manually from the “Circuit<br />

On/Off” menu (see page 13).<br />

Auxiliary functions are assign in<br />

the “Circ. Function” menu see<br />

page 26). AUX 1 can be assign to<br />

operate accessory equipment<br />

such as pool and spa lights.<br />

HEATER: Displays the heat source (Heater, Solar Prf., Solar)<br />

as specified in the “Heat” menu settings (see page 14). If heat is<br />

enabled, when the pool filter pump is switch on, the heat source<br />

is displayed.<br />

75° F / 85° F: Displays the actual spa or pool water temperature<br />

(75° F) and the set point temperature (85° F) as set in the<br />

“Heater” menu (see page 14). To adjust set temperature setting<br />

use the (-) TEMP and (+) TEMP buttons.<br />

Time: Displays the SunTouch system time as set in the “Clock”<br />

menu setting (see page 19).<br />

AIR 77°F AUX 1 2 3: Displays AUX 1, 2, 3 (lower line)<br />

11: 51AM AUX 123 when these auxiliary relay circuits are<br />

switched on. Press the AUX 1 (1) button to manually switch<br />

auxiliary 1 on or off. AUX 2, and AUX 3 can be switch on and off<br />

manually from the “Circuit On/Off” menu (page 13). Auxiliary<br />

functions are assign in the “Circ. Function” menu (page 26).<br />

AIR 77°F AUX D: “D” indicates the selected circuit<br />

11: 51AM AUX D (AUX 1,2,3) is in “delay” mode. For<br />

example, if AUX 2 is assigned to a cleaner, when the auxiliary<br />

circuit 2 is switched on via the “Circuit On/Off” menu setting, this<br />

will force the filter pump on for five (5) minutes before the<br />

cleaner pump switches on. See “Circuit Functions Menu” (page<br />

26) for more information.<br />

SunTouch Solar, Pool and Spa Control System Installation and User’s Guide