65<br />
SunTouch Pool/Spa Controller System Start-Up<br />
Perform the following start-up procedures to ensure that the SunTouch enclosure is installed correctly.<br />
Before you power up the SunTouch enclosure check the following:<br />
Check Electronics<br />
Check that the following plugs are seated correctly on the motherboard:<br />
• Relay connectors - PUMP - AUX1 - AUX2<br />
• Temperature sensors connectors WATER, SOLAR, AIR (J9)<br />
• Transformer wire harness (J10) attached to the motherboard.<br />
• Heater control connector GAS HEATER (J12) or two-wire screw terminal.<br />
Refer to "Summary System Installation Steps Summary," on page 37, and "SunTouch Motherboard<br />
Connections on page 51.<br />
SunTouch System Test<br />
The following describes how to test the main control panel to activate the heater, valves and pumps. Before<br />
testing the system, be sure that all pool and spa equipment has been properly installed and connected to the<br />
SunTouch enclosure.<br />
Testing Valve Actuators and Filter Pump<br />
Use the following steps to test the valve actuators (CVA24T - P/N 263045) for proper rotation.<br />
To test the valve actuators and pool/spa filter pump:<br />
1. Power up the SunTouch Power center.<br />
2. Press the MENU button. Circuit On/Off is displayed. Press the Right arrow button access the pool<br />
filter pump circuit. Press the Up or Down arrow button and select ON. Press the Left arrow button<br />
to return to the main status screen. POOL and the temperature setting will be displayed as shown<br />
below.<br />
3. The pool filter pump should be operating. Water will be removed from the pool and returned to the<br />
pool.<br />
POOL 71°F / 91°F<br />
11: 51AM HEATER<br />
Testing the auxiliary relays<br />
To verify that AUX 1, AUX 2 and AUX 3 relays outputs are operating correctly:<br />
1. Power up the SunTouch Power center.<br />
2. Press the MENU button. Circuit On/Off is displayed. Press the Right arrow button access the AUX<br />
1 setting. Press the Up or Down arrow button and select ON. Press the Left arrow button to return<br />
to the main status screen. The auxiliary number will be displayed as shown below.<br />
3. Repeat step 2 to test AUX 2 and AUX 3 relay.<br />
AIR 71°F<br />
11: 51AM AUX123<br />