65<br />

SunTouch Pool/Spa Controller System Start-Up<br />

Perform the following start-up procedures to ensure that the SunTouch enclosure is installed correctly.<br />

Before you power up the SunTouch enclosure check the following:<br />

Check Electronics<br />

Check that the following plugs are seated correctly on the motherboard:<br />

• Relay connectors - PUMP - AUX1 - AUX2<br />

• Temperature sensors connectors WATER, SOLAR, AIR (J9)<br />

• Transformer wire harness (J10) attached to the motherboard.<br />

• Heater control connector GAS HEATER (J12) or two-wire screw terminal.<br />

Refer to "Summary System Installation Steps Summary," on page 37, and "SunTouch Motherboard<br />

Connections on page 51.<br />

SunTouch System Test<br />

The following describes how to test the main control panel to activate the heater, valves and pumps. Before<br />

testing the system, be sure that all pool and spa equipment has been properly installed and connected to the<br />

SunTouch enclosure.<br />

Testing Valve Actuators and Filter Pump<br />

Use the following steps to test the valve actuators (CVA24T - P/N 263045) for proper rotation.<br />

To test the valve actuators and pool/spa filter pump:<br />

1. Power up the SunTouch Power center.<br />

2. Press the MENU button. Circuit On/Off is displayed. Press the Right arrow button access the pool<br />

filter pump circuit. Press the Up or Down arrow button and select ON. Press the Left arrow button<br />

to return to the main status screen. POOL and the temperature setting will be displayed as shown<br />

below.<br />

3. The pool filter pump should be operating. Water will be removed from the pool and returned to the<br />

pool.<br />

POOL 71°F / 91°F<br />

11: 51AM HEATER<br />

Testing the auxiliary relays<br />

To verify that AUX 1, AUX 2 and AUX 3 relays outputs are operating correctly:<br />

1. Power up the SunTouch Power center.<br />

2. Press the MENU button. Circuit On/Off is displayed. Press the Right arrow button access the AUX<br />

1 setting. Press the Up or Down arrow button and select ON. Press the Left arrow button to return<br />

to the main status screen. The auxiliary number will be displayed as shown below.<br />

3. Repeat step 2 to test AUX 2 and AUX 3 relay.<br />

AIR 71°F<br />

11: 51AM AUX123<br />

SunTouch Solar, Pool and Spa Control System Installation and User’s Guide