80<br />

Installing the ESO Circuit Board (Continued)<br />

6. Connecting the ESO switch: Route a two-wire cable through grommet located on the left-side of<br />

the SunTouch Power Center, up into the low voltage raceway to the ESO switch circuit board.<br />

7. Connect the two wires to J13 on the ESO switch circuit board. Connect the other end of the cable to<br />

the emergency switch as shown below.<br />

8. Verify that all cable connections are connected correctly. Close the front panel and secure it with the<br />

retaining screw. The Emergency Shut-Off Switch installation is complete.<br />

Emergency shut-off<br />

circuit board<br />

A<br />

A<br />

B<br />

B<br />

C<br />

C<br />

D<br />

E<br />

F<br />

J13<br />

SHUT OFF<br />

+ -<br />

D<br />

E<br />

F<br />

Grommet<br />

(Low voltage raceway)<br />

2-wire connection<br />

SunTouch Power Center<br />

Emergency Shut-Off switch (ESO)<br />

SunTouch Solar, Pool and Spa Control System Installation and User’s Guide