80<br />
Installing the ESO Circuit Board (Continued)<br />
6. Connecting the ESO switch: Route a two-wire cable through grommet located on the left-side of<br />
the SunTouch Power Center, up into the low voltage raceway to the ESO switch circuit board.<br />
7. Connect the two wires to J13 on the ESO switch circuit board. Connect the other end of the cable to<br />
the emergency switch as shown below.<br />
8. Verify that all cable connections are connected correctly. Close the front panel and secure it with the<br />
retaining screw. The Emergency Shut-Off Switch installation is complete.<br />
Emergency shut-off<br />
circuit board<br />
A<br />
A<br />
B<br />
B<br />
C<br />
C<br />
D<br />
E<br />
F<br />
J13<br />
SHUT OFF<br />
+ -<br />
D<br />
E<br />
F<br />
Grommet<br />
(Low voltage raceway)<br />
2-wire connection<br />
SunTouch Power Center<br />
Emergency Shut-Off switch (ESO)<br />
SunTouch Solar, Pool and Spa Control System Installation and User’s Guide