Grounding and Bonding to the SunTouch Power Center<br />

Connect a ground wire from the primary electrical panel to the SunTouch ground bus bar. Also ground each<br />

piece of high voltage (120 VAC or 240 VAC) equipment that is connected to the SunTouch Power Center<br />

relays. The SunTouch Power Center must also be connected to the pool bonding system using an 8 AWG<br />

(minimum) wire. An earth terminal for bonding is provided on the grounding bus bar inside the Power Center.<br />

For input AC wiring information, see page 520.<br />

Grounding Bus Bar<br />

(three terminals for<br />

relays and one for main<br />

AC ground wire)<br />

SunTouch Solar, Pool and Spa Control System Installation and User’s Guide