SunTouch® - Pentair
SunTouch® - Pentair
SunTouch® - Pentair
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
69<br />
SunTouch Error Messages<br />
Error Messages<br />
If the system detects that a sensor is not connected to the SunTouch Power Center or it is defective, an error<br />
message is displayed in the Diagnostics menu (page 25). The following lists the sensor errors.<br />
Error<br />
Message<br />
Air Err (Displays on the Main<br />
Screen)<br />
Air Temperature Err (Displays in<br />
the "Diagnostics" menu)<br />
Water Temperature Err (Displays<br />
in the "Diagnostics" menu)<br />
Solar Temperature Err (Displays<br />
in the "Diagnostics" menu)<br />
Possible<br />
Cause<br />
Air sensor not connected to the<br />
SunTouch motherboard.<br />
Air sensor not connected to the<br />
SunTouch motherboard.<br />
Water sensor not connected to<br />
the SunTouch motherboard.<br />
Solar sensor not connected to<br />
the SunTouch motherboard.<br />
Solution<br />
Check that the air sensor plug is connected to J21<br />
connector on the motherboard. Check that the sensor<br />
wire is connected properly.<br />
Check that the air sensor plug is connected to J21<br />
connector on the motherboard.<br />
Check that the water sensor plug is connected to J21<br />
connector on the motherboard.<br />
Check that the solar sensor plug is connected to J21<br />
connector on the motherboard.<br />
Self Test Error Codes<br />
The “Self Test” feature is intended for use by service personnel. If after performing a control panel self test<br />
(see Diagnostics menu page 25) there were no errors detected, Code 0 is displayed, indicating that there were<br />
no problems and the test was successful. If a problem is detected during the test, an error code is displayed<br />
upon completion of the test. For example Code 1 would indicate a problem with the display. If multiple errors<br />
are detected, multiple code numbers are displayed. For example, Codes 4, 2, 1, would indicate problems<br />
detected with the buttons, LCD contrast, LCD backlight on the control panel.<br />
The following lists the control panel self test error codes.<br />
Error Code Table<br />
Error<br />
Code<br />
Code<br />
Code<br />
Code<br />
0<br />
1<br />
2<br />
Description<br />
PASS - The control<br />
no problems<br />
LCD backlight<br />
LCD contrast<br />
panel has<br />
C ode 4<br />
Switch (buttons)<br />
Code<br />
5<br />
UART loopback test<br />
Resetting the System Fuses<br />
The SunTouch Power Center provides two resettable fuses to protect the 18 VAC and 24 VAC circuits. The<br />
fuses are located on the front panel of the SunTouch Power Center. Press the fuse button to reset the fuse. See<br />
page 40 for fuse locations.<br />
SunTouch Solar, Pool and Spa Control System Installation and User’s Guide